Honeywell AlarmNet GSMBR Installation And Setup Manual page 36

Communications module
Table of Contents

Advertisement

GSMBR / iGSMBR Installation and Setup Guide
PROMPTS
Restore Zn8 Y/N
68
(Y)_
Delay Zn8 (secs)
69
(00)_
Prompts 70 thru 76 appear for the iGSMBR only.
Use DHCP Y/N
70
(Y)_
NIC IP Address:
71
255.255.255.255_
Subnet Mask:
72
255.255.255.255_
Gateway IP Addr:
73
255.255.255.255_
DNS Serv IP Addr:
74
255.255.255.255_
Enable Pwr Save
75
(Y)_
IP Connection
76
(Present)_
3-20
Programming for Zone Trigger, 4204 and Two-4204 Modes
4204/
ZONE
ENTRY
2-4204
TRIG.
2-
4204
only
2-
4204
only
OPTIONS
[Y], [N]
Enables restore reporting for zone 8.
[01-15]
Defines the reporting delay in seconds for zone 8.
[00] = no
delay
[Y], [N]
Dynamically allocates the IP addresses
(recommended); if [Y], then skip to Prompt 75:
"Enable Pwr Save". If [N], uses fixed IP
addresses.
12 digit:
Enter the 4-part address for this device. The 4
xxx.xxx.xxx.x
parts of the address must be separated by spaces
xx
(displayed as periods in Review mode).
12 digit:
Enter the 32-bit address mask used to indicate
xxx.xxx.xxx.x
the portion (bits) of the IP address that is being
xx
used for the subnet address. The 4 parts of the
address must be separated by spaces (displayed
as periods in Review mode).
12 digit:
Enter the 4-part address assigned to the
xxx.xxx.xxx.x
Gateway. The 4 parts of the address must be
xx
separated by spaces (displayed as periods in
[0.0.0.0.] =
Review mode).
not used
12 digit:
Enter the 4-part IP address assigned to the DNS
xxx.xxx.xxx.x
(Domain Name System) server. The 4 parts of
xx
the address must be separated by spaces
[0.0.0.0.] =
(displayed as periods in Review mode).
not used
[Y], [N]
For 24 hour Battery Backup requirement, this
feature must be enabled, or the unit must be
powered by an Uninterruptable Power Supply.
If connectivity problems occur with certain
routers or switches disable this option.
Present
Press the [space] key to toggle between the
options. Press [ENTER] to select the
Auto Detect
configuration.
If "Present" is chosen, it is assumed that IP is
connected to the device. If it is not detected, a
Primary Comm Path Failure message will be
delivered after the programmed fault time
expires.
If "Auto Detect" is chosen, the device will always
try to use IP to communicate but it will not
generate a Primary Comm Path Failure unless it
previously detected the presence of IP. As soon
as the presence of IP is detected, a Primary
Comm Path Restore message is generated and
the value of IP Connectivity programming
parameter is changed from "Auto Detect" to
"Detected".
From this point on, the software expects
connectivity. The auto detect logic will resume
DESCRIPTION