Honeywell AlarmNet GSMBR Installation And Setup Manual page 34

Communications module
Table of Contents

Advertisement

GSMBR / iGSMBR Installation and Setup Guide
PROMPTS
Delay Zn2 (secs)
39
(00)_
Rpt Zn2 ONLY if
40
Armed (N)_
If LYNX Panic is enabled, then skip to Prompt 45: "Rpt Zn3 ONLY if Armed."
Zn3 Trigger Type
41
(V+)_
Invert Zn3 Y/N
42
(N)_
Restore Zn3 Y/N
43
(Y)_
Delay Zn3 (secs)
44
(00)
Rpt Zn3 ONLY if
45
Armed (N)_
Zn4 Trigger Type
46
(V+)_
47
Invert Zn4 Y/N
(N)_
48
Restore Zn4 Y/N
(Y)_
Delay Zn4 (secs)
49
(00)
Rpt Zn4 ONLY if
50
Armed (N)_
Zn5 Trigger Type
51
(V+)_
Invert Zn5 Y/N
52
(N)_
3-18
Programming for Zone Trigger, 4204 and Two-4204 Modes
4204/
ZONE
ENTRY
2-4204
TRIG.
2-
4204
only
OPTIONS
[01-15]
Defines the reporting delay in seconds for zone 2.
[00] = no
delay
[Y], [N]
Reports alarms on zone 2 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 2.
• (EOLR)
Selects the triggering method for this zone input.
Press the [Space] key to scroll through choices.
• (V+)
• (V–)
[Y], [N]
Inverts the alarm and normal states of the zone
3 trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 3.
[01-15]
Defines the reporting delay in seconds for zone 3.
[00] = no
delay
[Y], [N]
Reports alarms on zone 3 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 3.
4204 mode: If any zone is programmed to
"Report Only if Armed," skip to Prompt 56:
"Enable Zn6."
• (EOLR)
Selects the triggering method for this zone input.
• (V+)
Press the [Space] key to scroll through choices.
• (V–)
[Y], [N]
Inverts the alarm and normal states of the zone
4 trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 4.
[01-15]
Defines the reporting delay in seconds for zone 4.
[00] = no
delay
[Y], [N]
Reports alarms on zone 4 ONLY if the
conditional zone (zone 7 in zone trigger mode;
zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 4.
• (EOLR)
Selects the triggering method for this zone input.
Press the [Space] key to scroll through choices.
• (V+)
• (V–)
[Y], [N]
Inverts the alarm and normal states of the zone
5 trigger; otherwise uses normal input signal.
DESCRIPTION