VISTA CONTROL PANEL
Figure 2-2. Wiring a VISTA for ECP Mode or 4204 Modes
To wire the module to a LYNXR-I, see Figure 2-3. Refer to the LYNXR-I Installation and
Setup Guide.
LYNX
SUPER HIGH
CAPACITY
BATTERY
(OPTIONAL) REQUIRED
FOR 24-HR BACKUP

Wiring for Zone Trigger Mode

You can use a security system's output (such as a bell output or voltage trigger), to trip the
Z1/Z2 zone on the communications module and thereby generate a report to the monitoring
station. The trigger can be a positive voltage, a ground, or a voltage change taken from a
security system zone that is supervised with an EOLR. Depending on which triggering
method is used, ensure the communications module Z1/Z2 zone is properly programmed.
For positive voltage tripping (V+) of zone Z1/Z2, the voltage must be within 2.0V-14V.
Trigger levels above this range may cause permanent damage to the unit. Trigger levels
below this range result in unreliable operation.
For ground voltage tripping (V–) of zone Z1/Z2, the voltage must be less than 1.0V.
RED
+12V AUX
BLK
GND
YEL
DATA OUT
GRN
DATA IN
4-WIRE CABLE (N4632-4)
LRR/IP COMMUNICATIONS PORT
LYNXR-I CONTROL PANEL
LYNX
STANDARD
CAPACITY
BATTERY
NOTE
DO NOT CONNECT THE COMMUNICATIONS MODULE BACKUP
BATTERY OR TRANSFORMER WHEN USING WITH LYNXR-I
Figure 2-3. Wiring a LYNXR-I for ECP Mode
TRANSFORMER
TB1
AC INPUT 1
1
AC INPUT 2
2
ECP (+) VOLTAGE INPUT
3
GND
4
5
ECP DATA IN
ECP DATA OUT
6
COMMUNICATIONS
MODULE
RED
BLK
YEL
GRN
Section 2: Mounting and Wiring
BATTERY
J1
TB1
1
2
3
ECP (+) VOLTAGE INPUT
GND
4
5
Z1/Z2 OR DATA IN
6
Z3 OR DATA OUT
COMMUNICATIONS
MODULE
2-3