GSMBR / iGSMBR Installation and Setup Guide

System Status Displays

The next seven displays make up a cycle of displays. Pressing the [Space] key advances you
to the next field in the cycle. Pressing the backspace [BS] key advances you to the last field
in the cycle (Line Voltage field).
[S]
5-2
Cntry Netw LAC
xxx xxx xxxxx
Cell BaseSt Chan
xxxxx
x
xxx
Second Site RSSI
-xxxdbm
ECP 67 TmPB
Flt
xx 5 ++
OK
1234 67 TmPB Flt
5555 xx 5 ++ OK
12345678 TmPB Flt
5555555x 5 ++ OK
1234567 TmPB Flt
5555555 5 ++ OK
S – Searching
D – Registration Denied
R – Registered Roaming
? – Unknown Registration State
Press the [Space] key to go to the next screen.
Press the backspace [BS] key to go to the last screen.
GSM Status Display Screen 2
Cntry – Country Code
Netw – Network Code
LAC – Local area code
Press the [Space] key to get to the next screen.
Press the backspace [BS] key to go to the previous field.
GSM Status Display Screen 3
Cell – Base Station ID
BaseSt – Base Station Antenna Sector
Chan – Control Channel in use
Press the [Space] key to go to the next screen.
Press the backspace [BS] key to go to the previous field.
GSM Status Display Screen 4
Secondary GSM Site RSSI level in dBm.
Press the [Space] key to go to the GSM Status Display
Screen 1.
Press the backspace [BS] key to go to the previous field.
ECP Mode
Displays the zone and system fault status.
Press the [Space] key to go to the next field.
4204 Emulation Mode
Displays the zone and system fault status.
Press the [Space] key to go to the next field.
Two-4204 Emulation Mode
Displays the zone and system fault status.
Press the [Space] key to go to the next field.
Zone Trigger Mode
The status of the module can be viewed on the 7720P.
The status display includes:
Zone input status (1234567) – The numbers 1-7
represent the 7 mappings of the zone input, and follow
Honeywell's ADEMCO high-speed format codes:
1=New Event
5=Normal
X=Not Enabled
Tm – Tamper status follows high-speed format codes
above.
P – Represents line voltage as follows:
+ =Power line voltage OK
– = Power line voltage bad and reported

Advertisement

loading

  Related Manuals for Honeywell AlarmNet GSMBR

This manual is also suitable for:

Alarmnet igsmbr