PROMPTS
10
Multi Mode
(Disabled)_
11
Multi Mode Addr
(12)_
Important Information Regarding Primary and Secondary Accounts (Prompts 12-18)
Account information is provided by the central station administrator. If the control supports secondary
account reporting, you will need secondary account information. The City ID, CS ID or Subscriber ID of the
secondary account must differ from that of the primary account.
12
Primary City ID
(??)_
13
Primary CS ID
(??)
14
Primary Sub ID
(????)
15
nd
En. 2
CS Y/N
(N)_
16
nd
2
City ID
(??)_
nd
17
2
CS ID
(??)_
nd
18
2
Sub ID
(????)_
19
Device Address
(03)_
Programming for ECP Mode
ENTRY
OPTIONS
• Disabled
• 4204 Sourced
• 2-4204 Sourced
[01-30]
[01-99]
[01-FE]
[0001-9999]
[Y], [N]
[01-99]
[01-FE]
[0001-9999]
[01-30]
DESCRIPTION
Enable if you want system events sent by email to the
user.
Select "4204 Sourced" to send up to four events (plus
two additional reports triggered by optional hardwire
zones 6 and 7), or "2-4204 Sourced" to send eight
events.
Disable for normal alarm processing and go to Prompt
12: "Primary City ID".
This address must be programmed if using the Multi-
Mode (email notification) feature. The device address
must be unique from the normal LRR Device Address
(Prompt 19) and the Keypad Address used for Remote
Access or Direct Wire downloading. The address used
must also be enabled as a 4204 relay module in Vista
and First Alert control panels.
See Important Information above.
Enter the 2-digit primary city ID, 01-99 (decimal).
Enter the 2-digit primary central station ID number,
01-FE (HEX).
Enter the 4-digit subscriber account number, 0001-
9999 (decimal).
Applicable only if control supports Central Station #1
and #2 Category Enable reporting for the LRR device
(e.g., VISTA-128BP, FA1660C, etc.).
Used if reporting to a second central station is desired.
If [N], go to Prompt 19: "Device Address."
Enter the 2-digit secondary city ID, 01-99 (decimal).
Enter the 2-digit second central station's ID number,
01-FE (HEX).
Enter the 4-digit subscriber account number for the
second central station, 0001-9999.
In ECP mode, the module communicates with the panel
as a Long Range Radio (LRR) device. Enter the
appropriate ECP device address. For VISTA-10 and
VISTA-20 series control panels, use address 03. For
other controls, see the control panel's Installation and
Setup Guide.
NOTES:
1. When programming the control, enable the LRR
output.
2. The device address must be unique from the "Keypad
Address" entered in Prompt 22, and the Multi-Mode
Address entered in Prompt 11.