Honeywell AlarmNet GSMBR Installation And Setup Manual page 22

Communications module
Hide thumbs

Advertisement

GSMBR / iGSMBR Installation and Setup Guide
PROMPTS
20
RemoteAccess Y/N
(N)_
21
Direct Wire Y/N
(N)_
22
Keypad Address
(28)_
23
Supervision
(24 Hours)_
Prompts 24 and 25 appear for the iGSMBR only.
24
GSM Rollover Y/N
(Y)_
25
GSM 24Hr Tst Y/N
(N)_
26
Old Alarm Time
10 Minutes_
3-6
Programming for ECP Mode
ENTRY
OPTIONS
[Y], [N]
[Y], [N]
[01-30]
• 30 Day
• 24 Hrs
• None
[Y] , [N]
[Y], [N]
• 10 Minutes
• 15 Minutes
• 30 Minutes
• 1 Hour
• 2 Hours
• 4 Hours
• 8 Hours
• 12 Hours
• 24 Hours
DESCRIPTION
Press [Y] to allow the end user to access their system
via a website. Availability of this service is controlled
by the dealer via the web-based programming tool on
the AlarmNet Direct website.
Applies only to control panels that support Direct Wire.
Enables Direct Wire Downloading over IP.
If [N], and if Prompt 20: "Remote Access" is disabled,
skip to Prompt 23: "Supervision."
This address must be programmed if using either the
Remote Access feature of Direct Wire downloading.
Enter the appropriate device address.
NOTES:
1. This address must also be programmed as an alpha
keypad in the control panel or an AUI (advanced user
interface) type device, if a full enhanced graphic
interface to the system is desired and the control
panel supports it. DO NOT connect an actual keypad
(or any other device) assigned to this address.
2. If using a compatible LYNXR-I series control (when
available), this address must be set to "1."
3. This address must be unique from the "Device
Address" entered in Prompt 19.
The AlarmNet network must hear at least one
message from the module during this supervision
period; otherwise, AlarmNet notifies the central station
that a communication failure has occurred. (If the
supervision period is changed after registration, you
must re-register the module.)
Press the [Space] key to scroll through choices.
If enabled, all messages (including AlarmNet network
supervisory messages) are sent over the GSM network
in the event of an Internet failure.
If disabled, all messages (except AlarmNet network
supervisory messages) are sent automatically over the
GSM network in the event of an Internet failure.
If enabled, the iGSMBR module sends a message once
a day to verify module operation. A "secondary
communication path loss" message is generated if the
message is not successfully delivered.
Sets how long an undeliverable alarm is retried for
delivery to the central station. If the message is not
validated, it is retried until the old alarm time is
reached or the message is validated.
Press the [Space] key to scroll through choices.