Deif SGC 120 User Manual page 45

Single genset controller
Hide thumbs Also See for SGC 120:
Table of Contents

Advertisement

No.
Alarms
Low Fuel level (Sensor)
4
Low Fuel level (Switch)
5
Low Water Level (Switch)
Auxiliary input/User defined
6
name
7
Anlg LOP Ckt Open
8
Engine Temp Ckt Open
9
Fuel Level Ckt Open
10
Fuel Theft
11
Emergency Stop
12
Fail To Stop
13
Fail To Start
14
L1 Phase Over Voltage
15
L2 Phase Over Voltage
16
L3 Phase Over Voltage
17
L1 Phase Under Voltage
18
L2 Phase Under Voltage
19
L3 Phase Under Voltage
20
DG Phase Reversal
USER MANUAL 4189341226A UK
Causes/Indication
Indicates that the amount of fuel level is below the preset
threshold. This condition is detected only when engine is
on.
Indicates that the amount of fuel level measured is low
through switch.
Indicates that radiator water level is below the preset
threshold.
Configured auxiliary input has triggered longer than preset
duration.
The oil pressure sensor is not detected (circuit open).
The temperature sensor is not detected (circuit open).
The fuel level sensor is not detected (circuit open).
The fuel consumption has exceeded the preset threshold.
Configured as digital input has triggered longer than preset
or when an immediate shutdown is required.
It is detected that genset is still running after sending stop
command.
Indicates that genset has not started after the preset
number of start attempts.
Indicates that genset (L1) phase voltage has exceeded the
preset over-voltage threshold.
Indicates that genset (L2) phase voltage has exceeded the
preset over-voltage threshold.
Indicates that genset (L3) phase voltage has exceeded the
preset over-voltage threshold.
Indicates that genset (L1) phase voltage has fallen below
preset under-voltage threshold.
Indicates that genset (L2) phase voltage has fallen below
preset under-voltage threshold.
Indicates that genset (L3) phase voltage has fallen below
preset under-voltage threshold.
Alternator phase sequence (L1-L2-L3) is not correct.
Actions
Shutdown
Warning
Shutdown
Warning
Electrical Trip
Notification
Shutdown
Warning
Electrical Trip
Notification
Shutdown
Warning
Electrical Trip
Notification
Shutdown
Warning
Electrical Trip
Notification
Shutdown
Warning
Electrical Trip
Notification
Shutdown
Warning
Electrical Trip
Notification
Warning
Shutdown
Shutdown
Shutdown
Shutdown
Warning
Shutdown
Warning
Shutdown
Warning
Shutdown
Warning
Shutdown
Warning
Shutdown
Warning
Shutdown
Warning
Electrical Trip
Notification
Page 45 of 72