Determining the Number of Supply Pipes Needed
Determine the dispenser's model number from the serial tag located on the side 1 lower rail of the
dispenser. Locate the model number in the chart below to determine the number of product pipes
required.
Step 1: Determine the type of supply line needed from the model number's 10th position. If the
model number is 2312FS-2XXR
pressurized supply line for each product. If the model number is 2312FS-2XXS (Note the S) the pump
will require a suction supply line for each product.
Step 2: Determine the number of product pipes required by finding the model number below.
( the use of X in the model number indicates a field where the entry in not important to this discussion.)
Model Number
Product Supply lines required
2311FS-1XXXX
Use 1 product line plumbed to position A.
2312FS-2XXXX
2322FS-1XXXX
Use 1 product line plumbed to position A.
2322FS-2XXXX
Use 1 product line plumbed to position D.
2324FS-2XXXX
2331FS-1XXXB
2332FS-2XXXB
2331FS-1XXXX
Use 1 product line plumbed to position A, for low grade product.
2332FS-2XXXX
Use 1 product line plumbed to position D, for high grade product.
2342FS-1XXXB
Use 1 product line plumbed to position B, non-blended product such as Diesel.
2344FS-2XXXB
2422FS-1XXXX
Use 1 product line plumbed to position A.
2424FS-2XXXX
Use 1 product line plumbed to position D.
2431FS-1XXXB
2432FS-2XXXB
2433FS-1XXXB
Use 1 product line plumbed to position B, for low grade product.
2436FS-2XXXB
Use 1 product line plumbed to position C, for high grade product.
2431FS-1XXXX
Use 1 product line plumbed to position A.
2432FS-2XXXX
Use 1 product line plumbed to position B.
2433FS-1XXXX
Use 1 product line plumbed to position D.
2436FS-2XXXX
2442FS-1XXXB
Use 1 product line plumbed to position A for low grade product.
2444FS-2XXXB
Use 1 product line plumbed to position D for high grade product.
Use 1 product line plumbed to position C; non-blended product such as Diesel.
2444FS-1XXXX
Use 1 product line plumbed to position A.
2448FS-2XXXX
Use 1 product line plumbed to position B.
Use 1 product line plumbed to position C.
Use 1 product line plumbed to position D.
(Note the R) the dispenser will require a submerged pump and
6
105894 Rev G 12-6-16