Connecting Pump Motor Power for Remote Dispensers

The remote dispensers require a submerged pump control relay box, such as Red Jacket or F.E. Petro
across the line starters. Check with those manufactures for information on control relay boxes.
Termination of Field Wiring for Pump Motor Power of Remote Dispensers
Follow the chart below by locating the model number of the dispenser you are installing in the chart.
The individual product wires are identified by the colors used in this manual. Connect the designated
wire to the power board terminal strip position as indicated in the chart. Warning the terminal sequence
does not necessarily follow the sequence of the products.
connects to the "A" product relay output and the "D" product relay output ( not the "B" as you might
expect). Connect the opposite end of the product control wire to the sub-pump relay box as below:
1st Product: Connect the Red 18ga. wire to the power distribution board as indicated in the chart
and the other end to the control relay box for your 1st product.
2nd Product: Connect the Brown 18ga. wire to the power distribution board as indicated in the
chart and the other end to the control relay box for your 2nd product.
3rd Product: Connect the Blue 18ga. wire to the power distribution board as indicated in the
chart and the other end to the control relay box for your 3rd product.
4th Product: Connect the Violet 18ga. wire to the power distribution board as indicated in the
chart and the other end to the control relay box for your 4th product.
Note: TS refers to Power Board Terminal Strip followed by the terminal number.
Model Number
2311or 2312
2322 or 2324
2331 or 2332 Mixer
2331 or 2332 Blender
2342 or 2344 blenders
2422 or 2424
2431 or 2432 Mixer
2431 or 2432 Blender
2433 or 2436
2433 or 2436 Blenders
2442 or 2444 Mixer
2442 or 2444 Blender
2444 or 2448
CAUTION: Use a separate circuit breaker for each pump motor. Make sure the pump motor is
never on the same circuit breaker as any other power circuit for the dispenser.
Wiring Remote Sub-Pump Control Wires
1st Product
2nd Product
Red to TS 7
Red to TS 7
Brown to TS 19
Red to TS 7
Brown to TS 11
Red to TS 7
Brown to TS 19
Red to TS 7
Brown to TS 11
Red to TS 7
Brown to TS 19
Red to TS 7
Brown to TS 11
Red to TS 7
Brown to TS 19
Red to TS 7
Brown to TS 11
Red to TS 11
Brown to TS 15
Red to TS 7
Brown to TS 11
Red to TS 7
Brown to TS 15
(Diesel)
Red to TS 7
Brown to TS 11
20
For example a two product dispenser
3rd Product
4th Product
Blue to TS 19
Blue to TS 19
Blue to TS 19
Blue to TS 19
Blue to TS 15
Violet to TS 19
(Diesel)
Blue to TS 19
Blue to TS 15
Violet to TS 19
105894 Rev G 12-6-16

Advertisement

Table of Contents
loading