General Errors - Sav 876.17 Operating Instructions Manual

Control unit
Table of Contents

Advertisement

Available languages

Available languages

SAV 876.17
9 APPENDIX
9.4.2

General errors

Display
Error no.
E5000
"F!- Prog.start"
E5001
"F!- Firmware"
E5002
"F!- Prog.exec."
E5004
"F!- PWM freq."
"F!- CRC int.
E5005
prog."
E5006
"F!- Menu conf."
E5007 /
"F!- Mains freq."
E5011
E5008
"F!- High temp."
E5009
"F!- En. relay"
E5010
"F!- Signal imp."
E5012
"No enable"
E5013
"F!- Calibr. HF"
Version 1.0
Error cause
Clear text
Error when starting the ma-
gnetising/demagnetising
program
Firmware error
Error during program
execution
The mains frequency
seems to be unstable.
The configuration is faulty
and could not be stored in
the menu.
The menu settings could
not be stored in the confi-
guration.
No mains frequency detec-
ted. The mains frequency
seems to be unstable. The
mains frequency is outside
the permissible limits.
The temperature in the de-
vice is too high, shutdown
is imminent.
Error when testing the
enable relay.
No enable, because the
magnetising command is
active for too long.
No enable as the set
holding force is lower than
the minimum holding force
level.
No enable, because the
current for the set holding
force level does not ex-
ceed the calibrated current
flow at the minimum
holding force.
General error messages
Measures for error
localisation
 
Contact service
 
Contact service
 
Contact service
If the error recurs,
check whether there is
Initiate external interference
strong interference in
suppression measures
the power supply.
Restart the device.
 
If this does not eliminate the
error, contact service
Restart the device.
 
If this does not eliminate the
error, contact service
If the error recurs,
check whether there is
Initiate external interference
strong interference in
suppression measures
the power supply.
Check whether the
ambient temperature
Ensure sufficient cooling
is > 40 °C
If the error recurs, contact
 
service.
Adapt the external PLC
signals, if necessary. Do
Check impulse signals
not press the buttons on the
on the signal inputs
handheld control unit too
long.
Check the setting
Increase the holding force
for the holding force
level or increase the level
level, on the display if
after checking in the menu
applicable
"Min. hold. force lev.".
Check the mains
Increase the mains voltage,
voltage. The value
increase the cable cross-sec-
must not drop by more
tions of the supply line if ne-
than 10% of the no-
cessary. If necessary, repeat
minal value, including
the calibration process for
during the clamp/
the current for the minimum
release impulses.
holding force level.
[
]
117
Error elimination
Comment
Request replace-
ment device, if
necessary
Request replace-
ment device, if
necessary
Request replace-
ment device, if
necessary
 
 
 
If this does not
eliminate the error,
contact service
Check for hot
spots in the control
cabinet or direct
exhaust air flow
from devices
nearby.
 
The signal must
not be active for
longer than 2.5 s.
Always check
that the set min.
holding force
is sufficient for
machining.
Check for changes
in the environ-
ment which have
occurred since the
first calibration
EN