SAV 876.17
9 APPENDIX
9. APPENDIX
The safety information from item 2 Safety must be observed.
9.1
Technical data and environmental conditions
9.1.1
Dimensions and weight
Width (housing/with clamps)
Height (basic device/overall)
Depth
Weight
9.1.2
Electric characteristics
Supply voltage
Output voltage on the magnet con-
nection
Max. power consumption
Voltage on the control interface
9.1.3
Information regarding DIN EN ISO 13849-1
The control unit was designed based on the rules of functional safety as per DIN EN ISO 13849-1,
with the following features:
architecture, logic, safety features as per category 2
■
performance level 2
■
the MTTFd of the safety blocks is 30.45 years.
■
Conditions for use and environment
WARNING!
The devices are designed for air cooling. The cooling air flow must not be obstructed.
Version 1.0
110 mm / 135 mm
185 mm / 220 mm
200 mm
4000 g
200 VAC ±10%, 50 Hz/60 Hz
230 VAC ±10%, 50 Hz/60 Hz
400 VAC ±10%, 50 Hz/60 Hz
180 VDC ±10 %
210 VDC ±10 %
360 VDC ±10 %
30 A, impulse
24 VDC ±10 %
Risk of electric shock or destruction of the device!
Failure to protect the device and comply with regulations results in a risk of
electric shock or destruction of the device.
To prevent safety hazards for device and operators, the control unit has
■
to be reliably protected against splash water, steam, vapours, dust and
chips/swarf.
The device is intended for installation in an IP54 control cabinet.
■
The relevant regulations must be observed.
■
[
107
]
EN