Mitsubishi Electric Q Series User Manual page 88

Motion controller
Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

2 SYSTEM CONFIGURATION
Setting display of axis No.
(Note) : Correspondence between dno. and axis select rotary switch of servo amplifiers is shown below.
dno.
d01
d02
d03
d04
d05
d06
d07
d08
(Note) : The dno. is number of servo amplifier axis displayed with the system setting of MT Developer2.
(3) Setting of the axis No. and axis select rotary switch of servo
amplifier
Axis No. is used to set the axis numbers of servo amplifiers connected to
SSCNET connector in the program. Axis No. of 1 to 16 can be set.
Axis No. is set in the system setting of MT Developer2. Axis No. (1 to 16) is
allocated and set for the setting axis number (d01 to d16) of servo amplifier.
Since the axis number (d01 to d16) of servo amplifier on the system setting
screen corresponds to axis select rotary switch (0 to F) of servo amplifier, set the
axis select rotary switch referring to the table below.
Set the axis No. relative to axis number (dno.).
Correspondence between dno.s and axis select switches of servo amplifier
SSCNET
Axis select rotary switch
(Note)
system
of servo amplifier
1
1
1
1
1
1
1
1
Axis No. is set relative to dno. in the system settings.
REMARK
The setting of axis select rotary switch is different depending on the servo amplifier.
Refer to the "Servo amplifier Instruction Manual" for details.
dno.
(Note)
"0"
d09
"1"
d10
"2"
d11
"3"
d12
"4"
d13
"5"
d14
"6"
d15
"7"
d16
2 - 59
Axis select rotary switch
(Servo amplifier)
8
SSCNET
Axis select rotary switch
system
of servo amplifier
1
"8"
1
"9"
1
"A"
1
"B"
1
"C"
1
"D"
1
"E"
1
"F"