Mitsubishi Electric Q Series User Manual page 85

Motion controller
Hide thumbs Also See for Q Series:
Table of Contents

Advertisement

2 SYSTEM CONFIGURATION
Signal name
If a separate power supply is applied to the manual pulse generator/incremental synchronous
encoder, be sure it is 5V voltage. Anything else may cause a failure.
Always wire the cables when power is off. Not doing so may damage the circuit of modules.
Wire the cable correctly. Wrong wiring may damage the internal circuit.
(6) Connection examples of manual pulse generator
Manual pulse generator
(Voltage-output/Open-collector type)
Q173DPX
HA
HB
SG
SG
SG
P5
Shield
FG
: 1 to 3
(Note-1) : The 5V(P5)DC power supply from the Q173DPX must not be used if a separate power supply is
applied to the manual pulse generator/incremental synchronous encoder.
If a separate power supply is used, be sure it is 5V voltage. Anything else may cause a failure.
(Note-2) : Connect HPSEL
type)/incremental synchronous encoder is used.
Manual pulse
Q173DPX
generator side
Signal name
A
B
0V
5V
(Note-1)
:Twisted pair cable
HPSEL
to the SG terminal if the manual pulse generator (differential-output
CAUTION
2 - 56
Manual pulse generator
(Differential-output type)
HA P
HA N
HB P
HB N
SG
P5
FG
Shield
SG
(Note-2)
: 1 to 3
Manual pulse
generator side
A
A
B
B
0V
5V
(Note-1)
:Twisted pair cable

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q170mcpu