4 INSTALLATION AND WIRING
• Putting in the duct
Motion
controller
(Note-1)
30mm(1.18inch)
or more
(d) Twisting
If SSCNET cable is twisted, it will become the same stress added
condition as when local lateral pressure or bend is added. Consequently,
transmission loss increases, and the breakage of SSCNET cable may
occur at worst.
(e) Disposal
When incinerating optical cable (cord) used for SSCNET cable, hydrogen
fluoride gas or hydrogen chloride gas which is corrosive and harmful may
be generated. For disposal of SSCNET cable, request for specialized
industrial waste disposal services who has incineration facility for disposing
hydrogen fluoride gas or hydrogen chloride gas.
(f) Wiring process of SSCNET
Put the SSCNET cable in the duct or fix the cable at the closest part to
the Motion controller with bundle material in order to prevent SSCNET
cable from putting its own weight on SSCNET connector.
Leave the following space for wiring.
Top of panel or wiring duct
30mm(1.18inch)
or more
10mm(0.39inch)
or more
cable
40mm(1.58inch)
or more
Servo amplifier
Panel
90mm(3.54inch)
or more
(Note-1) : Fit the Motion controller at the left side of the servo amplifier.
4 - 19
100mm
(3.94inch)
or more
135mm(5.31inch)