Processing time of transition conditional expressions (continued)
Classifications
Symbol
<
<=
Comparison
operation
>
>=
Instruction
#0<#1
D800<D801
U3E1\G10000<U3E1\G10001
#0L<#2L
Less than
D800L<D802L
(Completion of condition)
U3E1\G10000L<U3E1\G10002L
#0F<#4F
D800F<D804F
U3E1\G10000F<U3E1\G10004F
#0<=#1
D800<=D801
U3E1\G10000<=U3E1\G10001
#0L<=#2L
Less than or equal to
D800L<=D802L
(Completion of condition)
U3E1\G10000L<=U3E1\G10002L
#0F<=#4F
D800<=D804F
U3E1\G10000F<=U3E1\G10004F
#0>#1
D800>D801
U3E1\G10000>U3E1\G10001
#0L>#2L
More than
D800L>D802L
(Completion of condition)
U3E1\G10000L>U3E1\G10002L
#0F>#4F
D800F>D804F
U3E1\G10000F>U3E1\G10004F
#0>=#1
D800>=D801
U3E1\G10000>=U3E1\G10001
#0L>=#2L
More than or equal to
D800L>=D802L
(Completion of condition)
U3E1\G10000L>=U3E1\G10002L
#0F>=#4F
D800F>=D804F
U3E1\G10000F>=U3E1\G10004F
Operation expression
APP - 63
Processing time [µs]
Q170MCPU
1.5
2.5
2.0
2.5
2.0
3.5
1.5
2.5
1.5
2.5
3.5
1.5
2.5
1.5
2.5
2.0
3.5
2.0
2.5
1.5
2.5
2.0
4.0