2 SYSTEM CONFIGURATION
Item
Self diagnostic error
(Error related for Multiple CPU)
Rotary switch
0
Rotary switch
0
Be sure to turn OFF the Motion controller's power supply before the rotary switch setting change.
7-segment LED
POINTS
(1) An error is displayed at the 7-segment LED, confirm the error code etc. using
MT Developer2.
(2) Refer to the Motion CPU error batch monitor of MT Developer2 or error list of
Programming Manual for error details.
(6) Rotary switch assignment
(a) Rotary function select 1 switch (SW1)
(Note)
Setting
0
Normal mode
A
Installation mode
(b) Rotary function select 2 switch (SW2)
(Note)
Setting
0
Mode operated by RAM
6
Mode operated by ROM
Ethernet IP address
8
display mode
C
SRAM clear
" AL" flashes 3 times
Steady " A1" display
(Self-diagnosis error)
4-digits error code is
displayed in two sequential
flashes of 2-digits each.
(ex. error code [3012])
Mode
Normal operation mode
Installed the operating system software using
MT Developer2
Mode
Normal operation mode
(Operation by the setting data and parameters
stored in the RAM built-in Motion controller.)
Mode to operate based on the setting data and
parameters wrote to the FLASH ROM built-in
Motion controller.
Mode to display the Ethernet IP address.
SRAM "0" clear
CAUTION
2 - 28
Remark
Setting error of the Multiple CPU system
Refer to the "Q173DCPU/Q172DCPU Motion
controller Programming Manual (COMMON)" for
details.
Description
(Note): Not to be set except above setting.
Description
(Note): Not to be set except above setting.