Calibrating The Empty State; Calibrating The Full State - Fronius Robacta Reamer V Easy Operating Instructions Manual

Welding torch cleaning
Hide thumbs Also See for Robacta Reamer V Easy:
Table of Contents

Advertisement

Calibrating the
empty state
Calibrating the
full state
20 mm (0.79 in.)
2 - 6 s
> 6 s
Drain the parting agent container until
1
the parting agent level is at least 20
mm (0.787 in.) below the sensor
Establish a power supply to the sensor
2
Press the "OUT OFF" button for
3
between 2 and 6 seconds
-
The LED on the sensor flashes
slowly
-
After releasing the "OUT OFF"
button the LED goes out - the
sensor has detected a low fluid
level
Fill the parting agent container with
1
parting agent
Press the "OUT OFF" button for at
2
least 6 seconds
-
The sensor LED flashes slowly at
first, then more rapidly after 6
seconds
-
After releasing the "OUT OFF"
button the LED goes out - the
sensor has detected a high fluid
level