Screwing the Robacta Reamer V Easy, Robacta
Reamer V to the underlying surface
Screwing the
cleaning device
and installation
Danger from machines falling or toppling over.
stand to the
This can result in serious injury and damage to property.
underlying sur-
face
Screw on the cleaning device and the spatter tray retainer using the fixings supplied with
the cleaning device.
3
Place components on the installation stand and secure
WARNING!
Always secure the installation stand to the underlying surface.
The screws for fastening the installation stand are not included in the scope of sup-
ply of the installation stand. The installer is responsible for selecting the right type of
screws or bolts.
Always secure the cleaning device to the installation stand.
Place the optionally available installa-
1
tion stand on a level, firm and vibra-
tion-free surface (foundation)
-
Position the installation stand in
such a way that the distance the
robot has to travel to the cleaning
device on the installation stand is
as short as possible
Tightly screw the installation stand to
2
the surface (foundation) using the
selected mounting materials
41