Fitting The Fill-Level Control Sensor - Fronius Robacta Reamer V Easy Operating Instructions Manual

Welding torch cleaning
Hide thumbs Also See for Robacta Reamer V Easy:
Table of Contents

Advertisement

Fitting the fill-
1
level control
sensor
2
3
62
(2)
(2)
(3)
* *
* * * *
1 1
1
1
NOTE!
First press the upper part of the sensor
into the installation adapter as shown -
the sockets (1) on the installation
adapter must fit into the recesses (2) in
(1)
the sensor.
(1)
When the upper part of the sensor is prop-
erly lined up in the installation adapter,
press the sensor fully into the installation
adapter - the latch (3) on the installation
adapter must snap back over the sensor
(sensor audibly engages).
*
Use the fixings supplied with the
sensor.
Screw the installation adapter and sensor
on to the parting agent container housing
**
Fixings are not included in the
sensor/installation adapter scope
of supply. The installer is respons-
ible for selecting the right type of
fixing.
NOTE!
Ensure the fixings do not damage the
parting agent container.