Manually checking Robacta Reamer V functions

Safety

For the following tasks, the cleaning device must be supplied with compressed air.
This results in danger from the rotating cleaning cutter, cleaning motor moving up/
down, gas nozzle clamping device moving out/in, flying parts (chips, etc.), com-
pressed air/parting agent mixture escaping from the parting-agent injection nozzle.
This can result in serious injury and damage to property.
Manually check-
NOTE!
ing Robacta
When the slot for the "Lifting device up/down", "Spray in parting agent" and
Reamer V func-
"Clamp gas nozzle/Cleaning motor on" screws is positioned horizontally, function
tions
is deactivated.
1
2
The following must be checked when the functions are being performed:
-
-
3
Clamp gas nozzle/cleaning motor on
The following must be checked when the function is being performed:
-
WARNING!
Keep your body, especially your hands, face, hair, any objects and all clothing away-
from the cleaning cutter, cleaning motor, lifting device, gas nozzle clamping
device,wire cutter and parting-agent injection nozzle..
Wear ear protection!
Wear protective goggles with side protection.
Disconnect the cleaning device from the robot control
Establish a compressed air supply to the cleaning device
operation of the gas nozzle clamping device
function of cleaning motor
how far the cleaning cutter is inserted into the gas nozzle
4
2
1
0
1
Deactivating the functions
1
69