Troubleshooting
Errors in program
The parting agent does not spray
sequence
Parting agent container is full
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Welding torch is poorly cleaned or damaged
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Not enough spray
Adjust spray time
Parting agent hose suction filter in the parting agent container is soiled
Clean the suction filter of the parting agent hose with compressed air (for
more detailed information, see section
nebuliser
from page 58)
No signal from robot
Check robot program
Parting-agent injection nozzle blocked
Clean parting-agent injection nozzle
Contact After-Sales Service (arrange for parting-agent injection nozzle to be
replaced)
Vacuum pump faulty
Contact After-Sales Service (arrange for vacuum pump to be replaced)
Mechanical fault on solenoid valve
Contact After-Sales Service (arrange for solenoid valve to be replaced)
Position of the cleaning motor has been set incorrectly
Set the position of the cleaning motor correctly - see section
lifting device
from page
49
Gas nozzle clamped in wrong position
Adjust the gas nozzle clamping device - see section
clamping device
from page
Cleaning cutter not suited to welding torch shape
Fit the correct cleaning cutter
Cleaning cutter is worn
Replace cleaning cutter
Starting up the parting agent
Adjust gas nozzle
47
Adjusting the
91