3. Electrical connection
3.2
Electrical Connection data
Electrical appliances:
Model
Unit size
Connection power
[kW]
400V
Power - convection
[kW]
400V
Power - steam
[kW]
400V
Power - motor
[kW]
400V
Rated current
400V
max. permitted power
impedance Z
sys
Rated connection
[mm²]
average*
Connection power
[kW]
200V
Power - convection
[kW]
200V
Power - steam
[kW]
200V
Power - motor
[kW]
200V
Rated current
200V
max. permitted power
impedance Z
sys
Rated Connection
[mm²]
average*
Connection power
[kW]
230V
Power - convection
[kW]
230V
Power - steam
[kW]
230V
Power - motor
[kW]
230V
Rated current
230V
max. permitted power
impedance Z
sys
Rated Connection
[mm²]
average *
* Recommended connecting line laid open to the air for max. 5 m long!
The maximum permitted power impedance at the electrical connection point must not be
exceeded!
6.10
6.20
3/N/PE ~ 400 V 50/60Hz
11.5
19.9
10.5
18.9
9.9
16.5
0.8
0.8
[A]
15.7
26.6
0.627
0.252
[Ω]
5 x 4
5 x 6
3/PE ~ 200 - 240 V 50/60Hz
11.8
20.2
10.5
18.9
9.9
16.5
1.1
1.1
[A]
33.3
53.1
0.239
0.151
[Ω]
5 x 6
5 x 16
11.8
20.2
10.5
18.9
9.9
16.5
0.8
0.8
[A]
27.6
46.6
0.239
0.151
[Ω]
5 x 6
5 x 16
40
OEB / OES
10.10
10.20
12.20
19.9
34.4
34.4
18.9
33
33
16.5
26.4
29.7
0.8
1.2
1.2
26.6
48.0
48.0
0.252
0.113
0.113
5 x 6
5 x 16
5 x 16
20.2
34.7
34.7
18.9
33
33
16.5
26.4
29.7
1.1
1.5
1.5
53.1
95.8
95.8
0.151
-
-
5 x 16
5 x 35
5 x 35
20.2
34.7
34.7
18.9
33
33
16.5
26.4
29.7
0.8
1.2
1.2
46.6
83.9
83.9
0.151
-
-
5 x 16
5 x 35
5 x 35
EN
20.10
20.20
39.7
68.6
37.8
66
29.7
39.6
1.7
2.4
52.8
95.4
0.125
-
5 x 16
5 x 35
40.2
69.2
37.8
66
29.7
39.6
2.2
3.0
105.6
191.0
-
-
5 x 35
5 x 95
40.2
69.2
37.8
66
29.7
39.6
1.7
2.4
92.7
167.3
-
-
5 x 35
5 x 95