2 Pry the cartridge loose. It should pop out easily.
3 Slide the fuseholder cartridge completely out of the enclosure.
Prying cartridge
Figure 5-1 Removing the Fuseholder Cartridge
4 Remove the fuse clip insert from the fuseholder cartridge.
The fuse clips, conductors, and fuses are mounted on this cartridge. Pull up
the plastic retainer on the fuseholder cartridge and slide the insert away
from the cartridge, as shown in Figure 5-2.
5 Once the fuse clip insert is clear of the fuseholder cartridge, pry the spent
fuse from the fuse clip with the screwdriver.
6 Replace the old fuse with a new fuse of the same type, size, and rating.
Use a 3-A, 250-V fast-blow fuse (5 mm by 20 mm).
WARNING: For continued protection against fire hazard, replace the fuse
only with a fuse having the same type and rating.
ATTENTION: Pour éviter le risque d'incendie, ne remplacer que par des
fusibles de même type et valeur de courant.
7 Reinstall the fuse clip insert in the cartridge so that the plastic retainer locks
it in place.
8 Reinstall the fuseholder cartridge in the receptacle.