Download Print this page

3Com CS/3000-48 Installation Manual page 103

Cs/3000 series communications server

Advertisement

B-6
A
B: S
PPENDIX
16-Port
Asynchronous
Module Error
Message
M
TARTUP
ESSAGES
mean that the data test for RAM failed at address 0x4000010. The data that
was expected was 0x0100. The actual data was 0xFFFF.
Startup Test on Auxiliary Processor Board Failed
Meaning:
The auxiliary processor board failed startup tests administered
by communications server software.
Status Register - Failed
Channel Attention Interrupt Bit Not Set
Meaning:
The status register's channel attention interrupt bit is not set.
Status Register - Failed
NMI Bit Not Set
Meaning:
The status register's NMI bit is not set.
Status Register - Failed
TIC Interrupt Bit Not Set
Meaning:
The status register's TIC interrupt bit is not set.
TIC Interrupt Test - Failed
Meaning:
The TIC interrupt did not occur.
Timer <x> Test - Failed
Meaning:
One of the 8254 timer's counters (1 or 2) failed its test.
The following error message indicates that a 16-port asynchronous module
has failed a self-test.
Startup Test Failed on 16-port Asynchronous Module in Slot <x>
Meaning:
The 16-port asynchronous module in slot <x> failed a startup
test. Slot 1 is the slot closest to the power supply; slot 2 is the
middle slot; slot 3 is the slot farthest from the power supply.

Advertisement

loading

This manual is also suitable for:

Cs/3000Cs/3100