Carrier WeatherExpert 48N2 Controls, Start-Up, Operation, Service, And Troubleshooting page 6

Packaged rooftop cooling units with gas heat, optional electric heat, or hydronic heat and comfortlink controls version 10.x
Table of Contents

Advertisement

RUN
SERVICE
TEMPERATURES
STATUS
TEST
Auto View of
Service Test Mode
Run Status
(TEST)
Temperatures
(VIEW)
Local Machine
Econ
Disable
Refrigerant
Run Status
(STOP)
Temperatures
(ECON)
Soft Stop
Cooling
Request
Information
(S.STP)
(COOL)
Supply Fan
VFD
Request
Information
(FAN.F)
(VFDS)
Test Independent
Mode
Outputs
Trip Helper
(INDP)
(TRIP)
Test Fans
Ctl Temp
(FANS)
RAT,SAT,
or ZONE
(TEMP)
Calibrate Test
Actuators
(ACT.C)
CCN
Linkage
(LINK)
Test
Humidimizer
(HMZR)
Compressor
Run Hours
(HRS)
Test Circuit
EXVS
(EXVS)
Compressor
Starts
(STRT)
Test Cooling
(COOL)
Software
Version
Test Heating
Numbers
(HEAT)
(VERS)
Auto Component
Diag. Test
(AC.DT)
Table 2 — Navigator Menu Display Structure
PRESSURES
SETPOINTS
Air
Air Pressures
Occupied Heat
(AIR.P)
Setpoint
(AIR.T)
(OHSP)
Refrigerant
Pressures
Occupied Cool
(REF.P)
Setpoint
(REF.T)
(OCSP)
Unoccupied
Heat Setpoint
(UHSP)
Unoccupied
Cool Setpoint
(UCSP)
Heat - Cool
Setpoint
(GAP)
VAV Occ
Cool On
(V.C.ON)
VAV Occ
Cool Off
(V.C.OF)
Supply Air
Setpoint
(SASP)
Supply Air
Setpoint Hi
(SA.HI)
Supply Air
Setpoint Lo
(SA.LO)
Heating Supply
Air Setpoint
(SA.HT)
Tempering
Purge SASP
(T.PRG)
Tempering in
Cool SASP
(T.CL)
Tempering in
Vent Occ SASP
(T.V.OC)
Tempering in
Vent Unocc.
SASP
(T.V.UN)
INPUTS
OUTPUTS
CONFIGURATION
General Inputs
Fans
Unit Configuration
(GEN.I)
(FANS)
(UNIT)
Cooling Configuration
Compressor
Cooling
(COOL)
Feedback
(COOL)
(FD.BK)
Evap/Discharge
Heating
Temp. Reset
Thermostat
(HEAT)
(EDT.R)
Inputs
(STAT)
Actuators
Heating Configuration
(ACTU)
(HEAT)
Fire-Smoke
Modes
(FIRE)
General
Supply Static Press.
Outputs
Config.
(GEN.O)
(SP)
Relative
Humidity
(REL.H)
Economizer
Configuration
(ECON)
Air Quality
Sensors
(AIR.Q)
Building Press. Configs
(BP)
CFM Sensors
(CFM)
Cool/Heat Setpoint
Offsets
(D.LV.T)
Reset Inputs
(RSET)
Demand Limit Config.
(DMD.L)
4-20 Milliamp
Inputs
(4-20)
Indoor Air
Quality Config.
(IAQ)
Humidity Configuration
(HUMD)
Dehumidification
Config.
(DEHU)
CCN Configuration
(CCN)
Alert Limit Config.
(ALLM)
Sensor Trim Config.
(TRIM)
Switch Logic: NO/NC
(SW.LG)
Display Configuration
(DISP)
Supply Fan FVD
Config.
(S.VFD)
Exhaust Fan FVD
Config.
(E.VFD)
Filter Configuration
(FLTC)
Prognostics Config.
(PROG)
Evap Cond
Configuration
(EVP.C)
6
TIME
OPERATING
CLOCK
MODES
Time of Day
System
(TIME)
Mode
(SYS.M)
Month, Date,
Day and Year
HVAC Mode
(DATE)
(HVAC)
Local Time
Control Type
Schedule
(CTRL)
(SCH.L)
Mode
Local
Controlling
Holiday
Unit
Schedules
(MODE)
(HOL.L)
Daylight
Savings
Time
(DAY.S)
ALARMS
Currently
Active
Alarms
(CURR)
Reset All
Current
Alarms
(R.CUR)
Alarm
History
(HIST)