Carrier AIRSTREAM 42BHC Product Data

Carrier AIRSTREAM 42BHC Product Data

System fan coils
Hide thumbs Also See for AIRSTREAM 42BHC:

Advertisement

Copyright 2005 Carrier Corporation
Product
Data
42BHC UNIT
42BVC UNIT
AIRSTREAM™
42BHC,BVC
System Fan Coils
600 to 4000 Cfm
Carrier's versatile belted fan coil units
satisfy design requirements:
• A selection of 8 sizes covers
capacities from 600 to 4000 cfm
• Choice of motors, from
eliminates oversizing
• Wide range of coil options for 2-pipe
or 4-pipe systems
• Optional DX coils with expansion
valve and distributor
• Single and three-phase electric
heat (1.0 to 40 kW)

Features/Benefits

The 42BHC, BVC belt drive
fan coil units provide year-
round comfort air
conditioning with central
station operating economy.
A variety of coil options
reduces first cost
Four, 6 or 8-row cooling coils combine
needed capacities with the most effi-
cient heat transfer surface. For
4-pipe systems, select either of two
split-coil options. Coils consist of alu-
minum fins securely bonded to
OD seamless copper tubes. Each fin's
aluminum collar ensures accurate con-
trol of the fin spacing, while complete-
ly covering the tubes to lengthen coil
life. All coils also feature manual air
vents, with automatic air vent available
as an option.
1
/
to 5 hp,
4
1
/
-in.
2
Form 42B-1PD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AIRSTREAM 42BHC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carrier AIRSTREAM 42BHC

  • Page 1: Features/Benefits

    AIRSTREAM™ 42BHC,BVC Data System Fan Coils 600 to 4000 Cfm Carrier’s versatile belted fan coil units satisfy design requirements: • A selection of 8 sizes covers capacities from 600 to 4000 cfm • Choice of motors, from to 5 hp, eliminates oversizing •...
  • Page 2: Table Of Contents

    Fan wheels are designed to provided on the top and bottom of each One-inch matte surface, fiberglass provide low operating costs corner of the unit One-in. duct collars thermal/acoustical insulation lines the on discharge and on return are fur- fan coil cabinets to prevent sweating The forward-curved, centrifugal, nished standard.
  • Page 3: Model Number Nomenclature

    Model number nomenclature 42BH 42BH — Vertical Belt Drive Fan Coil Unit Coil — Rows 42BV — Vertical Belt Drive Fan Coil Unit B — 4, 2-Pipe L — 6, 2-Pipe H — 4/1, Same End Conn. C — Design K —...
  • Page 4: Options And Accessories

    Options and accessories electric heater data table for availability per unit) with 42BHC, BVC OPTIONS AND ACCESSORIES single-stage or multiple-stage, single power source. ITEM OPTION* ACCESSORY† Voltages: Automatic Air Vents Controls • 115 v, 208 v, 230 v and 277 v single-phase 60 Hz Electric Heat •...
  • Page 5 Thermostats — Three thermostats are available for field • programmable operating range, dead band, digital dis- installation: play, temperature set-back Honeywell T834C manual changeover, single-stage heat THERMOSTAT FUNCTIONS thermostat features: THERMOSTATS • off-cool-heat system switch SYSTEM FUNCTION CHANGEOVER Honeywell Honeywell Sunne •...
  • Page 6: Base Unit Dimensions

    Base unit dimensions 42BHC FAN COIL BASE UNIT (NO CONTROLS) DIMENSIONS (in.) UNIT Supply Duct Return Duct Mounting Holes 42BHC Fan Size Depth Width Height 9 x 4 9 x 6 10 x 4 10 x 7 11 x 10 12 x 9 12 x 12 15 x 12...
  • Page 7 42BHC FAN COIL WITH MOTOR CONTROL OPTION DIMENSIONS (in.) UNIT Supply Duct Return Duct Mounting Holes 42BHC Fan Size Depth Width Height 9 x 4 9 x 6 10 x 4 10 x 7 11 x 10 12 x 9 12 x 12 15 x 12 NOTES:...
  • Page 8 Base unit dimensions (cont) 42BHC FAN COIL WITH ELECTRIC HEAT OPTION DIMENSIONS (in.) UNIT Supply Duct Return Duct Mounting Holes 42BHC Fan Size Depth Width Height 9 x 4 9 x 6 10 x 4 10 x 7 11 x 10 12 x 9 12 x 12 15 x 12...
  • Page 9 42BVC FAN COIL BASE UNIT (NO CONTROLS) DIMENSIONS (in.) UNIT Supply Duct Return Duct 42BVC Fan Size Depth Width Height 9 x 4 9 x 6 10 x 4 10 x 7 11 x 10 12 x 9 12 x 12 15 x 12 NOTES: 1.
  • Page 10 Base unit dimensions (cont) 42BVC FAN COIL WITH MOTOR CONTROL OPTION DIMENSIONS (in.) UNIT Supply Duct Return Duct 42BVC Fan Size Depth Width Height 9 x 4 9 x 6 10 x 4 10 x 7 11 x 10 12 x 9 12 x 12 15 x 12 NOTES:...
  • Page 11 42BVC FAN COIL WITH ELECTRIC HEAT OPTION DIMENSIONS (in.) UNIT Supply Duct Return Duct 42BVC Fan Size Depth Width Height 9 x 4 9 x 6 10 x 4 10 x 7 11 x 10 12 x 9 12 x 12 15 x 12 NOTES: 1.
  • Page 12 Base unit dimensions (cont) 42BHC UNIT CORNER WEIGHTS (lb) RIGHT HAND UNIT LEFT HAND UNIT RIGHT-HAND UNITS LEFT-HAND UNITS UNIT TOTAL CONFIGURATION 42BHC WEIGHT No Heat With Heat No Heat With Heat No Heat With Heat No Heat With Heat No Heat With Heat No Heat...
  • Page 13 42BVC UNIT CORNER WEIGHTS (lb) LEFT HAND UNIT RIGHT HAND UNIT RIGHT-HAND UNITS LEFT-HAND UNITS UNIT TOTAL CONFIGURATION 42BVC WEIGHT No Heat With Heat No Heat With Heat No Heat With Heat No Heat With Heat No Heat With Heat No Heat With Heat No Heat...
  • Page 14: Accessory Dimensions

    Accessory dimensions MIXING BOX TOP VIEWS BOTTOM/REAR INLET TOP/REAR INLET RIGHT HAND SIDE VIEWS NOTE: All dimensions in inches. DIMENSIONS (in.) 42BHC,BVC UNIT SIZE 18.5 18.5 20.25 20.25 20.25 22.75 31.0 31.0...
  • Page 15 MIXING BOX RAILS FRONT VIEW SIDE VIEW NOTE: All dimensions in inches. DIMENSIONS (in.) DIMENSIONS (in.) UNIT UNIT 42BHC06 51.6 16.1 42BVC06 35.5 16.1 42BHC08 51.6 16.1 42BVC08 35.5 16.1 42BHC10 55.2 18.1 42BVC10 39.5 18.1 42BHC12 55.2 18.1 42BVC12 39.5 18.1 42BVC16...
  • Page 16 Accessory dimensions (cont) VALVE PACKAGES Basic — Basic valve package includes 2 or 3-way Deluxe — Deluxe valve package includes a circuit valves with balancing valves and 2 ball valvs. setter and a strainer in addition to the components listed under basic valve package. NOTE: All dimensions in inches.
  • Page 17 PIPING CONNECTION LOCATION DIAGRAM* Drain 2(51) 1-5/8(41) RH Tell-Tale LH Tell-Tale Use the table on the next page to determine the location of the piping LEGEND connections. For example, on a size 20 unit with 4 rows and a right CWR —...
  • Page 18 Accessory dimensions (cont) COIL ROWS DIMENSIONS (in.) 42BHC,BVC HEAT OPTIONS UNIT SIZE Cool Heat — — — — 06/08 — — — — — — — — — — — — 10/12 — — — — — — — — —...
  • Page 19: Application Data

    Application data Basic definitions UNIT HAND Unit hand — When facing the supply air outlet from the front of the unit (air blowing in your face), your right hand will be the right hand side of the unit and your left hand the left hand side of the unit.
  • Page 20 Application data (cont) PIPING COMPONENTS (cont) FACTOR RATING* SYMBOL/SKETCH DESCRIPTION BALANCE VALVE: Variable water flow manual bal- ancing valve with screwdriver slot adjustment screw. Application — Often used in conjunction with test port fittings for water flow balancing. Balance by temperature differential or coil pressure drop (check specifications for service fittings required if balancing by pressure drop).
  • Page 21 PIPING COMPONENTS (cont) FACTOR RATING SYMBOL/SKETCH DESCRIPTION 2-WAY MOTORIZED VALVE: Electric 2-position flow control valve (open/closed). Normally closed body with manual override lever. Installed in supply line to unit. Application — All standard control and valve SPRING RETURN packages are based upon normally closed valves (valve electrically powered open and closed by spring return when electric power removed).
  • Page 22: Selection Procedure

    Selection procedure This selection procedure provides a guide to determine SC = SCb x Cs x Es unit performance of the 42BHC, BVC units. Capacity = 34.2 x .96 x 1.00 tables (in Performance Data) are based on nominal cfm. = 32.83 MBtuh Correction factors are provided for other operating condi- a) Calculate water pressure drop (or refer to the Water...
  • Page 23: Performance Data

    Performance data 42BHC,BVC AIRFLOW CORRECTION FACTORS DIRECT EXPANSION (DX) CORRECTION FACTORS CFM RATIO CORRECTION FACTOR % OF TOTAL (Ct) SENSIBLE (Cs) (Actual/Base) NOMINAL CFM Total Sensible 1.40 1.25 1.26 0.95 0.93 1.35 1.22 1.23 0.97 0.96 1.30 1.19 1.20 1.00 1.00 1.25 1.16...
  • Page 24 Performance data (cont) 42BHC, BVC NOMINAL COOLING CAPACITIES 42BHC,BVC NOMINAL HEATING CAPACITIES UNIT SIZE HEATING CAPACITY COOLING* NOMINAL CFM ROWS 42BHC,BVC (MBtuh) UNIT SIZE NOMINAL COIL Total Sensible 42BHC,BVC ROWS 27.0 Capacity Capacity (MBtuh) (MBtuh) 46.9 23.3 16.0 27.0 17.9 13.8 46.9 12.8...
  • Page 25 42BHC,BVC 4-ROW COOLING CAPACITY (by Gpm) 75 F DB/ 63 F WB 80 F DB/67 F WB 85 F DB/71 F WB UNIT SIZE 40 F EWT 45 F EWT 50 F EWT 40 F EWT 45 F EWT 50 F EWT 40 F EWT 45 F EWT 50 F EWT...
  • Page 26 Performance data (cont) 42BHC,BVC 8-ROW COOLING CAPACITY (by Gpm) 75 F DB / 63 F WB 80 F DB / 67 F WB 85 F DB / 71 F WB UNIT 40 F EWT 45 F EWT 50 F EWT 40 F EWT 45 F EWT 50 F EWT...
  • Page 27 42BHC, BVC 6-ROW COOLING CAPACITY (by ∆T) 75 F DB/63 F WB 80 F DB/67 F WB 85 F DB/71 F WB UNIT ∆T 40 F EWT 45 F EWT 50 F EWT 40 F EWT 45 F EWT 50 F EWT 40 F EWT 45 F EWT 50 F EWT...
  • Page 28 Performance data (cont) DIRECT EXPANSION (DX) BASE COOLING CAPACITIES* (MBtuh) — 4-ROW COIL ENTERING-AIR TEMPERATURE (F)—DRY BULB/WET BULB CONNECTION UNIT R-22 SIZE(in.) SIZE SUCTION 75/63 80/63 75/67 80/67 80/71 85/71 42BHC,BVC TEMP(F) Liquid Suction 13.5 13.5 18.7 18.8 11.7 13.5 13.6 13.3 12.0...
  • Page 29 DIRECT EXPANSION (DX) BASE COOLING CAPACITIES* (MBtuh) — 6-ROW COIL ENTERING AIR TEMPERATURE (F) — DRY BULB/WET BULB CONNECTION UNIT R-22 SIZE (in.) SIZE SUCTION 75/63 80/63 75/67 80/67 80/71 85/71 42BHC,BVC TEMP (F) Liquid Suction 15.4 11.1 13.6 13.6 20.8 11.1 20.8...
  • Page 30 Performance data (cont) UNIT HORSEPOWER DATA TABLE TOTAL STATIC PRESSURE (in. wg) UNIT SIZE BLOWER 42BHC,BVC Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp 677 0.05 770 0.07 857 0.09 937 0.11 1009 0.13 1077 0.14 1140 0.16 1200 0.18 1257 0.20 729 0.07 798 0.09...
  • Page 31 UNIT HORSEPOWER DATA TABLE (cont) TOTAL STATIC PRESSURE (in. wg) UNIT SIZE BLOWER 42BHC,BVC Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp — — — — — — — — —...
  • Page 32 Performance data (cont) 42BHC,BVC COMPONENT STATIC RESISTANCE (in. wg) WET COIL DRY COIL TWO-INCH ONE-INCH TWO-INCH TWO-INCH UNIT NOMINAL PLEATED CABINET PLEATED THROWAWAY PLEATED SIZE 42BHC,BVC MERV 11 FILTER FILTER FILTER FILTER 0.02 0.08 0.12 0.16 0.01 0.02 0.04 0.06 0.08 0.03 0.02 0.03...
  • Page 33 42BHC,BVC WATER PRESSURE DROP (ft. wg) FOR CV FACTOR AND WATER FLOW RATE (GPM) WATER FLOW RATE (GPM) FACTORS 0.5 1.0 1.5 2.0 9.5 10.0 10.5 11.0 11.5 12.0 13.0 14.0 15.0 16.0 17.0 18.0 19.0 20.0 0.9 3.6 8.1 14.4 22.5 32.4 —...
  • Page 34: Typical Wiring Schematics

    Typical wiring schematics BASE UNIT, SINGLE-PHASE POWER MOTOR CONTROL/DISCONNECT OPTION SINGLE-PHASE POWER...
  • Page 35 BASE UNIT, THREE-PHASE POWER MOTOR CONTROL/DISCONNECT OPTION THREE-PHASE POWER...
  • Page 36 Typical wiring schematics (cont) 2-PIPE COOLING ONLY WITH SINGLE-SPEED FAN OPERATION AND HONEYWELL THERMOSTAT NOTES: 1. Optional valves are field wired. 2. No HW valve with electric heat. 2-PIPE OR 4-PIPE HEATING/COOLING WITH SINGLE-SPEED FAN OPERATION AND HONEYWELL DIGITAL THERMOSTAT NOTES: 1.
  • Page 37: Electrical Data

    — — 208-3-60 — — — The UL listing signifies that Carrier’s fan coil units have been examined 230-3-60 — — 14.0 by UL and comply with the organization’s applicable standards of U.S. and Canadian national product safety standard, UL 1995/CSA C22.2 460-3-60 —...
  • Page 38: Controls

    Controls Standard control features • 8-pole control terminal strip • Auto reset temperature limit switch • 4 in. x 4 in. junction box • Manual reset backup temperature limit switch NOTE: Motor leads are wired to the 4 in. x 4 in. junction •...
  • Page 39: Guide Specifications

    HVAC Guide Specifications — 42B the drain pan shall be insulated with -in. closed Size Range: 600 to 4000 Nominal Cfm cell insulation. Carrier Model Number: C. Fans: 42BHC (Horizontal Fan Coil Unit) Belt-driven, double-width fan wheels shall have 42BVC (Vertical Fan Coil Unit) forward-curved blades and be statically and dynami- cally balanced.
  • Page 40: Guide Specifications

    1) Mixing boxes shall be preassembled at the factory and shipped separately with base rails. Carrier Corporation • Syracuse, New York 13221 9-05A 9-05 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

This manual is also suitable for:

Airstream 42bvc