Carrier WeatherExpert 48N2 Controls, Start-Up, Operation, Service, And Troubleshooting page 155

Packaged rooftop cooling units with gas heat, optional electric heat, or hydronic heat and comfortlink controls version 10.x
Table of Contents

Advertisement

POINT NAME
POINT DESCRIPTION
INPUTS
LIMSWTMP Staged Gas Limit Sw. Temp
LAT1SGAS
Staged Gas LAT 1
LAT2SGAS
Staged Gas LAT 2
LAT3SGAS
Staged Gas LAT 3
Not Used
Not Used
LP_A
Circuit A Liquid Pressure Transducer
LP_B
Circuit B Liquid Pressure Transducer
Not Used
Not Used
Not Used
Not Used
Not Used
Not Used
OUTPUTS
HTMG_CAP Modulating Gas Capacity
Not Used
Not Used
HS3
Relay 3 W1 Gas Valve 2
HS4
Relay 4 W2 Gas Valve 2
HS5
Relay 5 W1 Gas Valve 3
HS6
Relay 6 W2 Gas Valve 3
POINT NAME
INPUTS
DHDISCIN
Dehumidify Switch Input
DMD_SW1
Demand Limit Switch 1
DMD_SW2
Demand Limit Switch 2
PRES
Pressurized Input
EVAC
Evacuation Input
PURG
Smoke Purge Input
IAQIN
IAQ - Discrete Input
MARH_MA
MARH milliamps
OARH_MA
OARH milliamps
SPRH_MA
SPRH milliamps
RARH_MA
RARH milliamps
DMDLMTMA
4-20 mA Demand Signal
SASPRSET
Supply Air Setpnt. Reset
OAQ_MA, SPRST_MA OAQ milliamps, SP Reset milliamps
OACFM
Outside Air CFM
FLTS/FLT_PDT
Filter Status/Filter Pressure Drop Transducer
PFLTS, PFLT_PDT
Post Filter Status Input/Pressure Drop Transducer Thermistor
COMPRESSOR EXPANSION BOARD (CXB)
The CXB is used to provide additional compressor outputs and
CSB inputs. See Table 99.
EXPANSION VALVE CONTROL BOARD (EXV)
The EXV is used on all units to control the EXVs. The EXV
board is also used on Humidi-MiZer
vide control of the condenser and bypass modulating valves.
See Tables 100-102.
LOW VOLTAGE TERMINAL STRIP
This circuit board provides a connection point between the ma-
jor control boards and a majority of the field-installed accesso-
ries. See Table 103. The circuit breakers for the low voltage con-
trol transformers, interface connection for the Carrier Comfort
Table 97 — Staged Gas Control Board (SCB) Inputs and Outputs
Thermistor / Transducer (0-5V)
Thermistor / Transducer (0-5V)
Thermistor / Transducer (0-5V)
Thermistor / Transducer (0-5V)
Thermistor / Transducer (0-5V)
Thermistor / Transducer (0-5V)
Thermistor / Transducer (0-5V)
Thermistor / Transducer (0-5V)
Thermistor
Thermistor
4-20mA
4-20mA
Relay
Relay
Relay
Relay
Table 98 — Control Expansion Module (CEM) Inputs and Outputs
POINT DESCRIPTION
equipped units to pro-
®
TYPE OF I/O
I/O POINT NAME
TYPE OF I/O I/O POINT NAME CONTROL BOARD CONNECTOR
Switch
Switch
Switch
Switch
Switch
Switch
Switch
Transducer
(4-20mA)
Transducer
(4-20mA)
Transducer
(4-20mA)
Transducer
(4-20mA)
Thermistor
Thermistor
Thermistor
Thermistor
Thermistor
Network
(CCN) communication, and interface connection for
®
the Local Equipment Network (LEN) communication are also
located on the low voltage terminal strip.
INTEGRATED GAS CONTROL (IGC)
One IGC is provided with each bank of gas heat exchangers.
The quantity of IGC boards will range from 2 to 5 depending
on the size of the unit and whether the unit is low, medium or
high heat. The IGC controls the direct spark ignition system
and monitors the rollout switch, limit switches, and induced-
draft motor Hall Effect switch.
For units equipped with modulating gas heat, the IGC in the
modulating gas section uses a pressure switch in place of the
Hall Effect sensor. The IGC is equipped with a LED (light-
emitting diode) for diagnostics. See Table 104.
155
CONTROL BOARD CONNECTOR
AN1
SCB
AN2
SCB
AN3
SCB
AN4
SCB
AN5
SCB
AN6
SCB
AN7
SCB
AN8
SCB
AN9
SCB
AN10
SCB
AO1
SCB
AO2
SCB
RLY1
SCB
RLY2
SCB
RLY3
SCB
RLY4
SCB
DI1
CEM
DI2
CEM
DI3
CEM
DI4
CEM
DI5
CEM
DI6
CEM
DI7
CEM
AN7
CEM
AN8
CEM
AN9
CEM
AN10
CEM
AN1
CEM
AN2
CEM
AN3
CEM
AN4
CEM
AN5
CEM
AN6
CEM
PIN NO.
J5, 1-3
J5, 4-6
J5, 7-9
J5, 10-12
J5, 13-15
J6, 1-3
J6, 4-6
J6, 7-9
J7, 1-2
J7, 3-4
J8, 1-2
J8, 3-4
J9, 1-3
J9, 4-6
J9, 7-9
J9, 10-12
PIN NO.
J7, 1-2
J7, 3-4
J7, 5-6
J7, 7-8
J7, 9-10
J7, 11-12
J7, 13-14
J6, 1-3
J6, 4-6
J6, 7-9
J6, 10-12
J5, 1-2
J5, 3-4
J5, 5-6
J5, 7-8
J5, 9-10
J5, 11-12