APPENDIX F — BACNET COMMUNICATION OPTION (CONT)
POINT DESCRIPTION
User Defined Analog 6
User Defined Analog 7
User Defined Analog 8
User Defined Analog 9
User Defined Binary 1
User Defined Binary 10
User Defined Binary 11
User Defined Binary 12
User Defined Binary 13
User Defined Binary 14
User Defined Binary 15
User Defined Binary 16
User Defined Binary 17
User Defined Binary 18
User Defined Binary 19
User Defined Binary 2
User Defined Binary 20
User Defined Binary 3
User Defined Binary 4
User Defined Binary 5
User Defined Binary 6
User Defined Binary 7
User Defined Binary 8
User Defined Binary 9
VAV Occ. Cool Off Delta
VAV Occ. Cool On Delta
VFD Maximum Speed
VFD Minimum Speed
VFD1 Actual Motor Freq
VFD1 Actual Motor Power
VFD1 Actual Motor RPM
VFD2 Actual Motor Freq
VFD2 Actual Motor Power
VFD2 Actual Motor RPM
ZS CO2 Sensor Valid Status
ZS Humidity Sensor Valid Status
ZS Temp Sensor Valid Status
ZS Thermostat Config Alarm
LEGEND
BALM — BACnet Alarm
BAV
— BACnet Analog Value (UPC)
BP
— Building Pressure
CALM — Carrier Alarm
CAP
— Carrier Analog Point (MBB)
CBP
— Carrier Binary Point
DBC
— Dry Bulb Changeover
DCV
— Demand Controlled Ventilation
DDBC — Differential Dry Bulb Changeover
DEC
— Differential Enthalpy Changeover
DEW
— Dewpoint
EDT
— Evaporator Discharge Temperature
EXV
— Electronic Expansion Valve
IAQ
— Indoor Air Quality
IGC
— Integrated Gas Control
LAT
— Leaving Air Temperature
OAEC — Outdoor Air Enthalpy Changeover
OAT
— Outdoor Air Temperature
OAQ
— Outdoor Air Quality
R
— Read
RAT
— Return Air Temperature
RH
— Relative Humidity
SASP — Supply Air Set Point
SP
— Setpoint
SPT
— Space Temperature
VAV
— Variable Air Volume
VFD
— Variable Frequency Drive
W
— Write
NETWORK POINTS LIST (cont)
READ/
TYPE
CCN POINT NAME
WRITE UNITS
CAP
CAP
CAP
CAP
CBP
W
CBP
CBP
CBP
CBP
CBP
CBP
CBP
CBP
CBP
CBP
CBP
W
CBP
CBP
W
CBP
W
CBP
W
CBP
CBP
CBP
CBP
CAP
VAVOCOFF
R/W
CAP
VAVOCON
R/W
CAP
STATPMAX
R/W
CAP
STATPMIN
R/W
CAP
VFD1FREQ
CAP
VFD1PWR
CAP
VFD1RPM
CAP
VFD2FREQ
CAP
VFD2PWR
CAP
VFD2RPM
BBV
BBV
BBV
BBV
251
DEFAULT
RANGE
VALUE
°^F
1 to 25
°^F
0 to 25
%
100
0 to 100
%
20
0 to 100
R
0 to 500
R
kW
R
0 to 30000
R
10 to 500
R
R
BACNET
BACNET
OBJECT ID
OBJECT NAME
BV:2911
user_binary_1_1
BV:2912
user_binary_2_1
BV:2913
user_binary_3_1
BV:2914
user_binary_4_1
BV:2915
user_binary_5_1
AV:180
vavocoff_1
AV:181
vavocon_1
AV:188
statpmax_1
AV:189
statpmin_1
AV:80
vfd1freq_1
AV:81
vfd1pwr_1
AV:82
vfd1rpm_1
AV:93
vfd2freq_1
AV:94
vfd2pwr_1
AV:95
vfd2rpm_1