Download Print this page

Operational Check - Assa Abloy Corbin Russwin SE LP10 9600 Series Installation Instructions Manual

Exit device with melr

Advertisement

Installation Instructions
SE LP10 9600 Series Exit Device
With MELR
a.
Install Door Position Switch supplied with product:
• Drill 1" hole in door for magnet
• Drill 1" hole in frame for switch
b.
Wire to ElectroLynx
wiring diagram on previous page.
a. Insert key into cylinder and rotate.
b. With key rotated turn lever and check that latch retracts.
c. Check that push bar fully retracts the latch.
d. Close door: Ensure latch fully extends into strike and
does not bind.
Note: For fail safe trim cylinder will have to be tested after wiring
is complete and power is turned on.
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
9) Door Postion Switch Installation
frame harness as shown in
®

10) Operational Check

Door Position
Switch