Assa Abloy Corbin Russwin SE LP10 9600 Series Installation Instructions Manual page 26

Exit device with melr

Advertisement

10) Operational Check (Continued)
NOTE: Ensure LED operates as configured*:
LED remains green when panel asserts GREEN_LED signal
*For configurations with GREEN_LED override enabled (Alternate Indicator Configuration);
see Application Diagram #2 in Section 6.
Note: Once electrical wiring has been successfully
completed according to proper application,
perform the following:
a. Turn power ON.
b. Verify LED located on reader is ON (Red or Green)
depending on reader configuration
c. Present valid credential and verify LED and
sounder activity.
d. Verify valid card read at EAC Panel.
e. Verify system operation functions; i.e., when valid credential
is presented to reader the door unlocks.
Wiegand Test Unit
The ASSA ABLOY Wiegand Test Unit verifies your installation in
the field*. The test unit checks for proper wiring, card reader data
integrity, lock functionality including lock/unlock, door position
status, and request-to-exit (REX) status.
In addition, this tool provides product demonstration abilities to
highlight the product's features and capabilities.
*For directions on use, see operating
instructions provided with unit.
Installation Instructions
SE LP10 9600 Series Exit Device
Feature
12 or 24VDC solenoid lock vol-
tage adjustable
Operates as Fail Safe or Fail
Secure
"Learn" mode allows testing of
specific cards without program-
ming at panel level
Card reader data integrity is vali-
dated at test unit
Displays detailed Wiegand data,
including hexadecimal string and
total bits received
Displays measured end-of-line
resistor values (if applicable)
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
26
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
With MELR
WT1
WT2
X
X
X
X
X
X
X
X
X
X