Typical (UL294*-Compliant) SE LP10 Application Diagram #1
Tamper will trigger when reader is removed from door and tamper wiring is connected at the panel.
Reader
Actuator (ET)
*UL294 is a United States based standard.
12/24VDC System
12 Conductor
ElectroLynx Harness
From McKinney
SE LP10
9600
Series Lock
Reader Electronics Requires 12VDC Filtered and Regulated
**IMPORTANT: Pin 7 must be tied to earth ground in the access
control panel.
Wiring in accordance with the NEC, ANSI/NFPA 70
Fail secure installations are subject to approval of local AHJ
Fail secure installations shall permit use of Listed panic
hardware to allow emergancy exit from the protected area.
Failure to follow proper ESD safe grounding procedures could
lead to equipment failure.
6) Wiring Diagrams (Continued)
12V
Average
Peak
100mA
220mA
15mA
500mA
READER NEG - Black, 1
QC12 Electric
READER POS - Red, 2
Hinge From
McKinney
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
**EARTH GROUND - Brown, 7
TAMPER - Yellow, 8
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
8
Installation Instructions
SE LP10 9600 Series Exit Device
24V
Average
Peak
n/a
n/a
15mA
500mA
H
N
G
120 VAC
12-24VDC
12VDC
Input
-
+
-
+
(-)
12VDC
(+)
DATA 1
DATA 0
RX (NO)
RX (COM)
DPS
DPS
Input
Connection (+)
Unsupervised Open
Input
Connection (-)
Collector Tamper
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
With MELR
Power Supply
(By Others)
Electrical
Access
Control
Panel
(By Others)
Use (NC) for
Fail Safe
Operation
Lock Relay
(NO) Fail
Secure
Operation
Panel Circuitry
5VDC
1KΩ
1KΩ
A to D Converter
1KΩ