Lock operational check for devices with cylinders:
1. Insert key into cylinder and rotate. (There should be no friction against lock case, wire
harness or any other obstructions.)
2. The key will retract the latch, key should rotate freely. If the deadbolt is thrown, the key will
first retract the deadbolt and then the latch. Inside lever retracts latch and deadbolt, if
provided.
3. Use proximity card or PIN code set up with lock configuration tool. This should unlock
outside lever and allow latch to be retracted. Please see Network & Lock Configuration Tool
user manual (WFMN1) for more information.