Page 1
IN120 Exit Device Installation Instructions A8185A 04/16 Copyright 2016, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
Table of Contents Warning ...................2 General Description ..............3 Hardware Specifications ............3 Electronic Specifications ............3 Parts Breakdown ..............4 Rim Type 8877/8878 Exit Device Installation ......7 Mortise Type 8977/8978 Exit Device Insallation ....19 Operational Check..............31 Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
IN120 Exit Device General Description The IN120 WiFi lock offers the ease and flexibility of WiFi in a streamlined design, setting a new standard for aesthetics and performance. The IN120 uses IEEE 802.11 WiFi communication and a flexible feature set for easier, more cost-effective installations, allowing facilities to leverage their IT infrastructure to expand access control coverage to more doors.
IN120 Exit Device Parts Breakdown PART NO./ORDER ITEM DESCRIPTION QTY. STRING IN-220-EM01-[B]IP-B Reader assembly - black plastic IN-220-EM01-[B]IP-W Reader assembly - white plastic IN-220-EM01-[B]IP-MB-xxx** Reader assembly - black plastic with metal trim IN-220-EM01-[B]IP-MW-xxx** Reader assembly - white plastic with metal trim IN-220-EM01-[B]IPS-B Reader assembly - black plastic IN-220-EM01-[B]IPS-W...
Page 5
IN120 Exit Device Parts Breakdown (continued) 8877/8878 x ET x Lever Design IN120 Rim Exit Device ITEM PART No. DESCRIPTION REQ’D Cylinder Assembly (Reference Catalog for Available Cylinders) #12-24 x 1-7/8” Cylinder Screws Lever (Reference Catalog for Available Styles) 97-4105 Exit Trim (ET) With Cylinder 97-4106 Exit Trim (ET) Without Cylinder...
Page 6
IN120 Exit Device Parts Breakdown (continued) 8977/8978 x RT x Lever Design IN120 Mortise Exit Device ITEM PART No. DESCRIPTION REQ’D Cylinder Assembly (Reference Catalog for Available Cylinders) Lever (Reference Catalog for Available Styles) 97-4107 Exit Trim (ET) With Cylinder 97-4108 Exit Trim (ET) Without Cylinder 52-4845...
IN120 Exit Device Installation Instructions for 8877/8878 Rim Exit 1 Door Preparation Inside A. Verify Hand and Bevel of Door • Check hand of door. The exit device is non-handed and the trim is field reversible. Left Hand Right Hand Reverse Reverse •...
Page 8
IN120 Exit Device 2 Install Door Position Switch (DPS) Wood doors have 3/8” raceway to controller cutout and metal doors have 3/4” raceway to the controller cutout. Refer to template A8214. 1. Insert connector end of DPS through the raceway on the latch edge of the door (Fig.
Page 9
IN120 Exit Device 3 Mount Exit Device Chassis NOTE: Exit chassis harness consists of a 6-pin female connector and two different-sized ground lugs (Fig. 3A) 1. Feed 6-pin connector and larger ground lug straight through to outside of door (Fig. 3A, B) while feeding smaller ground lug into wire hole, up through wire channel and out through inside of door (Fig.
Page 10
IN120 Exit Device 4 Mount Exit Trim (ET) NOTE: For exterior applications, use ET gasket (52-0263) to seal between ET escutcheon and outside door surface. A. Connect motor harness adapter to chassis harness connector (Fig. 4A). B. For wood doors: Route ET wire harness connector through the cylinder hole, up and through the wire run channel to the controller cutout.
Page 11
IN120 Exit Device 5 Install Cylinder For devices without cylinder, go to Step 6 - Secure Exit Chassis. 1. While installing the rim cylinder, support the tail piece of the cylinder, verifying its engagement with the top hub of the exit chassis. Note: Be sure ET harness is clear of cylinder and tailpiece.
Page 12
IN120 Exit Device 7 Install Chassis Cover Secure chassis cover to chassis using (4) #8-32 x 5/16” oval head machine screws (Fig. 7). NOTE: Cable lengths exaggerated for illustrative purposes. Fig. 7 1-800-810-WIRE • www.sargentlock.com • A8185A...
Page 13
IN120 Exit Device 8 Outside Reader and Mounting Plate Installation 1. Orient the reader so the LED lens is at the top. 2. Feed the cable/connector through the door (from outside to inside). 3. Install the reader to the outside of door by aligning the mounting posts with the door preparation holes.
Page 14
IN120 Exit Device Outside Reader Installation (Continued) 4. Next feed the cables/connectors through the inside mounting assembly (and gasket if required*). 5. Insert and partially tighten (2) through-bolts prior to installation of connectors. NOTE: Cable lengths exaggerated for illustrative purposes. Gasket* Inside of Door Inside...
Page 15
IN120 Exit Device 10 Installation of Connectors 9-24VDC Power* CAUTION - Do not touch or allow debris to enter connector contacts. Secure the following connectors to their respective terminals (Fig. 9A, B): DPS (4-pin) A. Secure the 4-pin DPS connector. B.
Page 16
IN120 Exit Device 11 Installation of Inside Component Assembly 1. Insert top tabs of controller into slots on mounting plate (Fig.10). 2. Ensure proper alignment of board-to-board connectors while pivoting bottom of controller toward door until tab on bottom snaps securely into place on mounting plate.
Page 17
IN120 Exit Device 12 Battery Installation Before installing batteries for the first time: Remove pull tab from its position beneath the coin cell by pulling on tab in direction of arrows printed on tab (Fig. 11). 1. Place (6) “AA” alkaline batteries in the compartment, being careful to align polarity properly.
Page 18
IN120 Exit Device 14 Installation of Rail Assembly 1. Retrieve harness from end of rail. Harness has limited travel and can be damaged. 2. Attach harness to female connector on chassis. 3. Install rail and screws per exit device instructions. Fig.
IN120 Exit Device Installation Instructions for Mortise Type 8977/8978 Exit Device 1 Door Preparation Inside A. Verify Hand and Bevel of Door • Check hand of door. This exit device is handed and is not reversible. Left Hand Right Hand •...
Page 20
IN120 Exit Device 2 Install Door Position Switch (DPS) Wood doors have 3/8” raceway to controller cutout and metal doors have 3/4” raceway to the controller cutout. Refer to template A8215. 1. Insert connector end of DPS through the raceway on the latch edge of the door (Fig.
Page 21
IN120 Exit Device 3 Mount Mortise & Exit Device Chassis 1. Slide mortise lock into door and loosely secure with (2) flat head screws. NOTE: Exit chassis harness consists of a 6-pin female connector and ground lug (Fig. 3A) 2. Feed 6-pin connector and larger ground lug straight through to outside of door (Fig.
Page 22
IN120 Exit Device 4 Position Exit Trim (ET) NOTE: For exterior applications, use ET gasket (52-0263) as a seal between ET escutcheon and outside door surface. A. Connect motor harness adapter to chassis harness connector (Fig. 4). B. For wood doors: Route ET wire harness connector through the cylinder hole, up and through the wire run channel to the controller cutout.
Page 23
IN120 Exit Device 5 Install Cylinder For devices without cylinder, go to Step 6. 1. Secure the cylinder by threading into lock body (see Fig. 5A). 2. Verify that the key retracts latchbolt. Position cylinder so that the SARGENT logo is right-side up. Correct Incorrect Fig.
Page 24
IN120 Exit Device 7 Install Chassis Cover Secure chassis cover to chassis using (4) #8-32 x 5/16” oval head machine screws (Fig. 7). NOTE: Cable lengths exaggerated for illustrative purposes. Fig. 7 1-800-810-WIRE • www.sargentlock.com • A8185A...
Page 25
IN120 Exit Device 8 Outside Reader and Mounting Plate Installation 1. Orient the reader so the LED lens is at the top. 2. Feed the cable/connector through the door (from outside to inside). 3. Install the reader to the outside of door by aligning the mounting posts with the door preparation holes.
Page 26
IN120 Exit Device Outside Reader Installation (Continued) 4. Next feed the cables/connectors through the inside mounting assembly (and gasket if required*). 5. Insert and partially tighten (2) through-bolts prior to installation of connectors. Gasket* Inside Mounting Plate NOTE: Cable lengths exaggerated for illustrative purposes. Ground wire (Lock Body) Fig.
Page 27
IN120 Exit Device 9 Installation of Connectors 9-24VDC Power* CAUTION - Do not touch or allow debris to enter connector contacts. Secure the following connectors to their respective terminals (Fig. 9A, B): DPS (4-pin) A. Secure the 4-pin DPS connector. B.
Page 28
IN120 Exit Device 10 Install Inside Module Component Assembly 1. Insert top tabs of controller into slots on mounting plate (Fig. 10). 2. Ensure proper alignment of board-to-board connectors while pivoting bottom of controller toward door until tab on bottom snaps securely into place on mounting plate.
Page 29
IN120 Exit Device 11 Battery Installation Before installing batteries for the first time: Remove pull tab from its position beneath the coin cell by pulling on tab in direction of arrows printed on tab (Fig. 11). 1. Place (6) “AA” alkaline batteries in the compartment, being careful to align polarity properly.
Page 30
IN120 Exit Device 13 Installation of Rail Assembly 1. Retrieve harness from end of rail. Note: Harness has limited travel and can be damaged. 2. Attach harness to female connector on chassis. 3. Install rail and screws per exit device instructions. Note: This view shows rim exit device version.
IN120 Exit Device Operational Check 1. Insert key into cylinder and rotate (Fig. 15A). There should be no friction against lock case, wire harness or any other obstructions. 2. Check that the key retracts the latch. 3. The key should rotate freely. 4.