Mechanical Operational Check; Electrical Operational Check - Assa Abloy Sargent Harmony Series Installation Instructions Manual

Mortise lock with iclass se reader
Hide thumbs Also See for Sargent Harmony Series:
Table of Contents

Advertisement

Harmony Series H2 Mortise Lock
Operational Check
8
For 82280-82283 & 82270-82273 Function mortise locks with cylinders:
1. Insert key into cylinder and rotate: There should be no friction against
lock case, wire harness or any other obstructions.
2. The key will retract the latch: Key should rotate freely.
3. When the deadbolt is thrown: Ensure that the key retracts both the
deadbolt and the latch.
4. Inside lever: When used, ensure it retracts both the latch
and deadbolt (if provided).
5. Close door: Ensure latch and deadbolt fully extend
and do not bind.
Note: Once electrical wiring has been successfully
completed according to proper application, follow
the following steps:
1. Turn power ON.
2. Verify LED located on reader is ON (Red or Green
depending on reader configuration (See reader LED
Configuration).
3. Present proximity credential and verify LED and
sounder activity.
4. Verify valid card read at EAC panel.
5. Verify system operation functions; i.e., present valid Prox credential
to reader and unlock door.
**PHR, EOL, IDP Functions:
Additional troubleshooting available - contact 1-800-810-WIRE.
Wiegand Test Unit
The ASSA ABLOY Wiegand Test Unit verifies your installation in
the field. The test unit checks for proper wiring, card reader data
integrity, lock functionality including lock/unlock, door position
status, and request-to-exit (REX) status.
In addition, this tool provides product demonstration abilities to
highlight the product's features and capabilities.
A8027G • 800-810-WIRE (9473) • www.sargentlock.com
Feature
12 or 24VDC solenoid
lock voltage adjustable
Operates as Fail Safe or
Fail Secure
"Learn" mode allows
testing of specific cards
without programming at
the panel level
Card reader data inte-
grity is validated at test
unit
Works with SE LP10
Displays detailed
Wiegand data, including
hexadecimal string and
total bits received
Displays measured end-
of-line resistor values
(if applicable)
19
WT1
WT2
X
X
X
X
X
X
X
X
X
X
X
X

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sargent harmony h2

Table of Contents