Installation Instructions
SE LP10 9600 Series Exit Device
With MELR
5. Trim Assembly Instructions:
a. Check cylinder components:
Cylinders longer than 1-1/8" (29mm) require collars.
Refer to Cylinder Collar Chart (Fig. 5a).
(for Mortise, skip to Step 6)
b. If required, modify by cutting cylinder tailpiece:
Correct length is 1/16" to 3/16" (2 to 5mm)
beyond cylinder housing cam.
c. Assemble cylinder:
1. Insert cylinder housing prongs into matching notches of escutcheon.
2. Pass cylinder tailpiece through cylinder collar (if required) and slot in cylinder cam.
3. Fasten cylinder in escutcheon recess or collar using 2 mounting screws.
Do not overtighten screws.
d. Escutcheon Assembly (Fig. 5b):
The lever is handed (LHR shown).
Note: Lever Return Spring handing can be identified by color of the spring:
LHR: Part Number 651F618 (Red)
RHR: Part Number 651F628 (Blue)
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
7) Installation Instructions (Continued)
Rim Cylinder
Cylinder Collar
(if necessary)
Cam must be postitioned as shown
when cylinder tailpiece is assembled
Cylinder Collar Chart
Cylinder Length
Inches
1-1/8"
1-1/4"
1-1/2"
*Specify Finish
Escutcheon
Assembly
Fig. 5b
15
Collar
Millimeters
29mm
None
32mm
422F88*
38mm
686F98*
Fig. 5a
(Trim for SVR/CVR/Rim shown)
Cylinder
Housing
Cam