Download Print this page

Operational Check - Assa Abloy Corbin Russwin IN120 Installation Instructions Manual

Advertisement

IN120 / IN220
FE6600/BL6600/MP6600 Series
Multi-point Lock
Installation Instructions
7

Operational Check

There should be no friction against lock case, wire
harness or any other obstructions.
Try the inside lever:
Ensure it retracts latch and deadbolt (if installed).
Use a valid credential* that has been set up with the
Lock Configuration Tool to unlock outside lever and
retract latch.
Refer to Lock Configuration Tool user manual (WFMN1) for
information on how to configure and program locks.
NOTE: The credential should approach the inscription on
the reader as indicated in the figure on the right to ensure
that the credential is read properly.
Do not wave credential.
In all cases, perform the following checks:
For units without a keypad, add card using LCT
software* and test.
For units with a keypad, add pin and card using LCT
software* and test.
LED signaling:
After using a valid credential a green flash followed by
motor unlock indicates normal operation (lock unlocks).
After using a valid credential a green flash followed by (4)
beeps and (4) fast purple flashes – indicates low power.
Check the input voltage.
If the input voltage is low, disconnect lock from power
source and check power source voltage. If power source
voltage is correct, inspect lock wiring for a possible short.
If the lock loses power, it will flash rapid blue for
approximately one minute. Lock will default to
programmed fail safe or fail secure.
After that, the lock will no longer be functional.
When you have completed the tests, close the door, ensuring
latchbolt fully extends into strike plate without binding.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2019-2021 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
24