12. Install Mounting Plate and (optional) Fire plate:
a. NOTE: For fire-rated doors only. Secure mounting plate and fire plate using (2) #8 1-1/4"
Phillips pan head self-drilling screws provided (Fig. 12a). Ensure wires from reader are properly
routed under flap of fire plate.
b. Secure mounting plate using (2) remaining Phillips flat head self-drilling screws provided. Ensure
wires from reader are properly routed under flap of fire plate.
c. Place ground wire eyelet between upper right mounting plate hole and screw when securing
mounting plate (and fire plate if used) to door (Fig. 12a, b).
Configuration for Rim/CVR/Mortise
Configuration for SVR
Fig. 12c
7) Installation Instructions (Continued)
FIre Plate
Ground
wire
Mounting
Screws
Installation Instructions
SE LP10 9600 Series Exit Device
Fig. 12a
For non-fire rated door, use #8-5/8" Phillips pan
head screws (no fire plate required).