Installation Instructions
SE LP10 9600 Series Exit Device
With MELR
Alternate Indicator Configuration Application Diagram #2
Connect GREEN_LED input to switch controlled by panel. Shorting GREEN_LED to READER_NEG (Black) with
panel switch will override reader LED to keep it green.
12/24VDC System
12 Conductor
ElectroLynx Harness
From McKinney
*IMPORTANT: Pin 7 must be tied to earth ground in the access
control panel.
Wiring in accordance with the NEC, ANSI/NFPA 70
Fail secure installations are subject to approval of local AHJ
Fail secure installations shall permit use of Listed panic
hardware to allow emergancy exit from the protected area.
Failure to follow proper ESD safe grounding procedures could
lead to equipment failure.
**UL294, S319, & BHMA A156.25 currently not applicable to Alternate Indicator option
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
6) Wiring Diagrams (Continued)
Reader Electronics Requires 12VDC Filtered and Regulated
Average
Reader
100mA
Actuator (ET)
15mA
QC12 Electric
Hinge From
McKinney
12V
24V
Peak
Average
220mA
n/a
500mA
15mA
120 VAC
Input
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
*EARTH GROUND - Brown, 7
**GREEN_LED - Yellow, 8
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
9
Peak
n/a
500mA
H
N
G
12-24VDC
12VDC
-
+
-
+
(-)
12VDC
(+)
DATA 1
DATA 0
RX (NO)
Use (NC) for
RX (COM)
Fail Safe
Operation
DPS
DPS
(NO) Fail
Secure
Operation
Panel Circuitry
(NC)
(NO)
Power Supply
(By Others)
Electrical
Access
Control
Panel
(By Others)
Lock Relay
Panel Relay