Exit device with melr

Advertisement

Product
1-Black
2-Red
ACCESS CONTROL DEVICES: SE LP10 Mortise, ElectroLynx wire Color / Function assignments
SE LP10
12VDC
MELR
(Reader)
NEG
POS
SE LP10 (MELR) Application Diagram #3 (12/24VDC System)
When door is closed, the
DPS is electrically closed
Door
Position Switch (DPS)
SELP10
Reader
†Door Cable - 12 conductor
8F
8M
(length selected by door width)
4F
4M
Not used
MELR Exit
Device
†NOTE: All Door Cables, Frame
Cable and QC12 Hinge are
specified & ordered seperately
Wiring shown is inside door frame
*UL294, S319, & BHMA A156.25 currently not applicable to TAMPER or Alternate Indicator option
Average
Reader
100mA
MELR
n/a
6) Wiring Diagrams (Continued)
8 PIN CONNECTOR
3-White
4-Green
5-Orange
WIEGAND
WIEGAND
RX
DATA_1
DATA_0
NO
8F
8M
Not
used
4M
8F
8M
4M
4F
4M
4F
†QC12
Hinge
8-pin to 4-pin
8M
4F
8M
3 " Adaptor
Not
Not
Not
Harness
used
used
used
Required
Supplied
†Male to Male
Adaptor Door Cable
12 Conductor
(3" length typically)
12V
24V
Peak
Average
220mA
n/a
n/a
250mA
dogged
Installation Instructions
SE LP10 9600 Series Exit Device
6-Blue
7-Brown
8-Yellow
RX
EGND
TAMPER
GREEN_LED*
COM
EGND
OPEN
COLLECTOR
INPUT
120 VAC
Input
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
8F
8M
RX (COM) - Blue, 6
**EARTH GROUND - Brown, 7
*TAMPER - Yellow, 8
4F
4M
MELR NEG - Violet, 1
MELR POS - Gray, 2
Not Used - Pink, 3
EGND - Tan, 4
Unsupervised
Open Collector
Tamper
Peak
n/a
1A inrush
600mA
during
retraction
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
10
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
With MELR
4 PIN CONNECTOR
1-Violet
2-Gray
3-Pink
12/24 VDC
DPS
(LOCK RELAY)
NEG
POS
NC
H
N
G
12-24VDC
12VDC
-
+
-
+
(-)
12VDC
(+)
Use (NC) for
Fail Safe
Operation
(NO) Fail
EGND
Secure
Operation
DPS
Panel Circuitry
DPS
5VDC
Input
Connection (+)
Input
Connection (-)
Wiring in accordance with the NEC, ANSI/NFPA 70
Fail secure installations are subject to approval of local AHJ
Fail secure installations shall permit use of Listed panic
hardware to allow emergancy exit from the protected area.
Failure to follow proper ESD safe grounding procedures could
lead to equipment failure.
4-Tan
DPS
COM
Power Supply
(By Others)
Electrical
Access
Control
Panel
(By Others)
Lock
Relay
1KΩ
1KΩ
A to D
Converter
1KΩ