13. Install Inside Escutcheon:
Check electrical connections.
a. Feed excess ElectroLynx
b. Feed excess trim and exit device harnesses under head cover.
c. Install inside escutcheon using (2) #8-32 x 5/8" oval head screws (Fig. 13a).
Note: Be careful not to pinch wires between
escutcheon and door surface.
CAUTION:
Neatly fold wires onto themselves and into
the remaining space to prevent pinching wires
when mounting escutcheon.
Configuration for SVR
Fig. 13b
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
7) Installation Instructions (Continued)
wire harness back into door.
®
Fig. 13a