MAINTENANcE AND SErvIcE
9 Maintenance and Service
•
•
•
9.1 Maintenance intervals
Due to the design, the brake COMBISTOP Type 28 can only be checked when it is
removed. If correctly designed, the brake COMBISTOP Type 28 is maintenance-free.
9.2 Service
Service is required if, in accordance with the fault table, there are symptoms of damaged
or soiled coverings, unusual noises or smells.
cAUTION
9.2.1 Dismount the brake
► Disconnect the connecting cables from the voltage supply.
► If necessary, remove the fan from the shaft (to this end, refer to the instruction man-
► Remove the three socket screws.
► Pull the brake backwards from the shaft.
Figure 15:
36
Observe the general safety instructions.
The brake must not be under voltage during maintenance and repair work!
Protect electrical and electronic components from splash water.
Limbs crushed !
Securing the load!
► Mechanically secure the load against unintended movement.
► Release brake from load.
► Dismounting of the brake according to manual.
ual of the motor).
Dismount the brake