Technical Data; Operating Conditions; Climatic Environmental Conditions; Mechanical Environmental Conditions - KEB COMBISTOP 28 Installation Manual

Table of Contents

Advertisement

3 Technical Data

3.1 Operating conditions

3.1.1 climatic environmental conditions

Storage
Ambient temperature
Relative humidity
Storage height
Transport
Ambient temperature
Relative humidity
Operation
Ambient temperature
Relative humidity
Construction and degree of
protection
Site altitude
Table 2:
Climatic environmental conditions

3.1.2 Mechanical environmental conditions

Storage
Vibration limits
Shock limit values
Transport
Vibration limits
Shock limit values
Table 3:
Mechanical environmental conditions

3.1.3 Electrical operating conditions

requirement
Overvoltage category
Table 4:
Device classification
18
Standard
class
EN 60721-3-1
1K4
Standard
class
EN 60721-3-2
2K2
EN 60721-3-2
2K3
Standard
class
EN 60721-3-3
3K3
EN 60721-3-3
3K3
EN 60529
IP65
Standard
class
1M1
EN 60721-3-3
EN 60721-3-3
1M1
Standard
class
EN 60721-3-2
2M1
2M1
EN 60721-3-2
Standard
class
EN 60664-1
III
Notes
-25...55 °C
<50 % (without condensation)
Max. 3000 m above lea level
Notes
-25...60 °C
95 % at 40 °C (without condensation)
Notes
(optional -40...+60°C)
5...85 % (without condensation)
(without micro switch, without shaft sealing
ring, without hand release)
Max. 2000 m above lea level
Notes
Vibration amplitude 0.3 mm (2...9 Hz)
Acceleration amplitude 1 m/s² (9...200 Hz)
40 m/s²; 22 ms
Notes
Vibration amplitude 3.5 mm (2...9 Hz)
Acceleration amplitude 10 m/s² (9...200 Hz)
100 m/s²; 11 ms
Notes

Advertisement

Table of Contents
loading

Table of Contents