Wiring Schematic - Danfoss VLT AutomationDrive FC 301 Operating Manual

0.25–75 kw, enclosure sizes a-c
Hide thumbs Also See for VLT AutomationDrive FC 301:
Table of Contents

Advertisement

VLT® AutomationDrive FC 301/FC 302
Operating Guide

4.4 Wiring Schematic

3-phase
91 (L1)
power
92 (L2)
input
93 (L3)
95
88 (-)
DC bus
89 (+)
50 (+10 V OUT)
+10 V DC
0/-10 V DC to
53 (A IN)
+10 V DC
0/4–20 mA
0/-10 V DC to
54 (A IN)
+10 V DC
0/4–20 mA
55 (COM A IN)
12 (+24 V OUT)
13 (+24 V OUT)
18 (D IN)
19 (D IN)
20 (COM D IN)
27 (D IN/OUT)
29
32 (D IN)
33 (D IN)
37 (D IN)
Illustration 6: Basic Wiring Schematic
A
Analog
D
Digital
Read more in EMC-Compliant Installation.
Danfoss A/S © 2021.01
PE
10 V DC
15 mA 130/200 mA
+
S201
ON=0/4–20 mA
S202
OFF=0/-10 V DC
to +10 V DC
P 5-00
24 V
0 V
(D IN/OUT)
1)
24 V
0 V
1)
Switch mode
power supply
24 V DC
-
+
-
24 V (NPN)
0 V (PNP)
24 V (NPN)
(COM A OUT) 39
0 V (PNP)
24 V (NPN)
S801
0 V (PNP)
ON=Terminated
OFF=Open
5V
24 V (NPN)
0 V (PNP)
S801
RS485
(N RS485) 69
24 V (NPN)
interface
0 V (PNP)
– –
(P RS485) 68
24 V (NPN)
(COM RS485) 61
0 V (PNP)
1
Terminal 37 (optional) is used for Safe Torque Off
(STO). For installation instructions, refer to the VLT
Safe Torque Off Operating Guide. For FC 301, termi-
nal 37 is only included in enclosure size A1. Relay 2
and terminal 29 have no function in FC 301.
2
Do not connect cable shield.
Electrical Installation
(U) 96
(V) 97
(W) 98
(PE) 99
Motor
Brake
(R+) 82
resistor
(R-) 81
Relay 1
03
240 V AC, 2 A
02
01
Relay 2
1)
06
240 V AC, 2 A
05
400 V AC, 2 A
04
Analog Output
0/4–20 mA
(A OUT) 42
0 V
RS-485
2)
AQ267037727118en-000101 / 130R0300 | 17
: Chassis
: Ground
: PE
: Ground 1
: Ground 2
®

Advertisement