JUMO flowTRANS MAG S Series Safety Manual page 42

Electromagnetic flowmeter for the process industry and hygienic applications
Table of Contents

Advertisement

5 Ex-relevant data for operation in zones 2, 21 and 22
Table 1: Medium temperature depending on the lining and flange material
Model 406012/1-1, 406013/1-1, 406012/2-1, 406013/2-1
Materials
Lining
Hard rubber
Soft rubber
PTFE
PFA
Thick PTFE
ETFE
Model 406015/1-1, 406016/1-1, 406015/2-1, 406016/2-1
Lining
PFA
PFA
PFA
42
Flange
Steel
Stainless steel
Steel
Stainless steel
Steel
Stainless steel
Steel
Stainless steel
Steel
Stainless steel
Steel
Stainless steel
Process connec-
tion
Flange
Connection flange
Variable process
connection
Medium temperature (operating data)
Minimum
-10 °C (14 °F)
-15 °C (5 °F)
-10 °C (14 °F)
-15 °C (5 °F)
-10 °C (14 °F)
-25 °C (-13 °F)
-10 °C (14 °F)
-25 °C (-13 °F)
-10 °C (14 °F)
-25 °C (-13 °F)
-10 °C (14 °F)
-25 °C (-13 °F)
Medium temperature (operating data)
Material
Minimum
Stainless
-25 °C (-13 °F)
steel
-
-25 °C (-13 °F)
Stainless
-25 °C (-13 °F)
steel
Maximum
90 °C (194 °F)
60 °C (140 °F)
130 °C (266 °F)
180 °C (356 °F)
180 °C (356 °F)
130 °C (266 °F)
Maximum
180 °C (356 °F)
130 °C (266 °F)
130 °C (266 °F)

Advertisement

Table of Contents
loading

Table of Contents