JUMO flowTRANS MAG S Series Safety Manual page 34

Electromagnetic flowmeter for the process industry and hygienic applications
Table of Contents

Advertisement

4 Ex relevant data for operation in zones 1, 21 and 22
Table 2: Medium temperature (Ex data) for model 406012/1-1, 406013/1-1, 406015/1-1, 406016/1-1
IMPORTANT (NOTE)!
If the installation location for the device is classified as a potentially explosive area for gases and dust,
the temperature data in the "Gas & dust" columns in the table must be taken into consideration.
If the installation location for the device is only classified as a potentially explosive area for gases, the
temperature data in the "Gas" column in the table must be taken into consideration.
IMPORTANT (NOTE)!
Not thermally insulated: the sensor is not surrounded by pipe insulating material.
Thermally insulated: the sensor is surrounded by pipe insulating material.
T1
T2
T3
T4
T5
T6
T1
T2
T3
T4
T5
T6
a
Applies for model 406012/1-1, 406013/1-1
b
Applies for model 406015/1-1, 406016/1-1
c
Low temperature version (optional)
34
Ambient temperature
c
(-40 °C)
-20 °C to +40 °C
Not thermal-
Thermally
ly insulated
insulated
Gas
Gas
Gas
&
Dust
c
(-40 °C)
-20 °C to +50 °C
Not thermal-
ly insulated
Gas
Gas
Gas
&
&
Dust
Dust
130 °C
130 °
130 °C
120 °C
85 °C
70 °C
130 °C
130 °C
130 °C
125 °C
90 °C
75 °C
(-40 °C)
Thermally
Not thermal-
insulated
ly insulated
Gas
Gas
Gas
&
Dust
90 °C 30 °C 80 °C 40 °C
90 °C 30 °C 80 °C 40 °C
90 °C 30 °C 80 °C 40 °C
90 °C 30 °C 80 °C 40 °C
70 °C 30 °C 80 °C 40 °C
70 °C 30 °C 80 °C 40 °C
90 °C 30 °C 70 °C 40 °C
90 °C 30 °C 80 °C 40 °C
90 °C 30 °C 80 °C 40 °C
90 °C 30 °C 80 °C 40 °C
90 °C 30 °C 80 °C 40 °C
75 °C 30 °C 75 °C 40 °C
c
-20 °C to +60 °C
Thermally
insulated
Gas
Gas
Gas
&
&
Dust
Dust

Advertisement

Table of Contents
loading

Table of Contents