Mains Connection; Motor Connection With Terminal Strip X1B - KEB COMBIVERT F5 Installation Manual

Digital servo controller
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Installation and Connection

3.3.3 Mains connection

Mains connection 230 V 1-phase
3 x 1.5 mm²
1 x 230 V AC
Protection
• Fuse 10 A slow-blowing or power protective
switch
• RCD (residual current operated circuit-
breaker) type A or type B
• at DC-supply pay attention to the permis-
sible voltage range of the fuses
DC-connection 230 V-class
2 x 1.5 mm²
250...370 V DC

3.3.4 Motor connection with terminal strip X1B

• PE
Connection for earthing
• U, V, W Servo motor
• PA, PB Braking resistor
• T1, T2 Temperature sensor / switch
GB - 12
X1.A
--
++
L3
N
N/L2
L1
L1
PE
PE
X1.A
-
--
+
++
L3
N/L2
L1
PE
Mains connection 230 V 3-phase
4 x 1.5 mm²
3 x 230 V AC
Mains connection 400 V 3-phase
4 x 1.5 mm²
3 x 400 V AC
DC-connection 400 V-class
2 x 1.5 mm²
420...747 V DC
X1.A
--
++
L3
L3
L2
N/L2
L1
L1
PE
PE
X1.A
--
++
L3
L3
L2
L2
L1
L1
PE
PE
X1.A
-
--
+
++
L3
L2
L1
PE

Hide quick links: