Accessories For Assembly; Stem Protection Tube For Rising Valve Stem - AUMA SAEx Series Operation Instructions Manual

Multi-turn actuators, control unit: electronic (mwg) with actuator controls, acexc 01.2 non-intrusive
Hide thumbs Also See for SAEx Series:
Table of Contents

Advertisement

Assembly
4.5.

Accessories for assembly

4.5.1.

Stem protection tube for rising valve stem

Procedure
22
SAEx 07.2
SAEx 16.2 / SAREx 07.2
6.
Fasten screws crosswise to a torque according to table.
Table 11:
Tightening torques for screws
Threads
M6
M8
M10
M12
M16
M20
Figure 15: Assembly of the stem protection tube
[1]
Protective cap for stem protection tube (fitted)
[1]*
Option: Protective cap made of steel (screwed)
[2]
Stem protection tube
[3]
V-seal
1.
Seal all threads with hemp, Teflon tape, or thread sealing material.
SAREx 16.2 Control unit: electronic (MWG)
ACExC 01.2 Non-Intrusive Profinet
Tightening torque [Nm]
Strength class A2-80/A4 80
10
24
48
82
200
392