System:communicate:ethernet:autoip:enable; System:communicate:ethernet:cancel; System:communicate:ethernet:dgateway - Keysight Technologies N778 C Series Programming Manual

Polarization instruments
Table of Contents

Advertisement

Command:

:SYSTem:COMMunicate:ETHernet:AUTOip:ENABle

Syntax:
:SYSTem:COMMunicate:ETHernet:AUTOip:ENABle
Description:
Enable or disable whether IP addresses can be created automatically by the instrument. Automatic IP addressing is only
used if DHCP is enabled, but the instrument cannot find a DHCP server.
Parameters:
Boolean (0 | 1 | off | on)
Response:
None
Example:
:SYST:COMM:ETH:AUTO:ENAB 1
Command:

:SYSTem:COMMunicate:ETHernet:CANCel

Syntax:
:SYSTem:COMMunicate:ETHernet:CANCel
Description:
Undo all changes to the network parameters that have been made since the last save, reboot or ":syst:comm:eth:restart"
command.
Parameters:
None
Response:
None
Example:
:SYST:COMM:ETH:CANC
Command:

:SYSTem:COMMunicate:ETHernet:DGATeway

Syntax:
:SYSTem:COMMunicate:ETHernet:DGATeway
Description:
Set the default gateway.
Parameters:
string (Up to four groups of up to 3 digits, groups separated by ".". Groups with leading zeros are interpreted as octal
numbers.)
Response:
None
Example:
:syst:comm:eth:dgat "192.168.101.11"
Command:
:SYSTem:COMMunicate:ETHernet:DGATeway?
Syntax:
:SYSTem:COMMunicate:ETHernet:DGATeway?
Description:
Get the default gateway.
Keysight N778xC Series Polarization Instruments Programming Guide
Instrument Setup and Status