HVAC400X – APPLICATION MANUAL
V2.2.15 Analog OUTPUT 1 (ID 81)
This monitoring value indicates the value of the analog output as a percentage of the used range.
V2.2.16 MOTOR PREHEAT (ID 1228)
This monitoring value indicates the status of the motor preheat function.
V2.2.17 DRIVE STATUS WORD (ID 43)
This monitoring value indicates the bit-coded status of drive.
V2.2.18 LAST ACTIVE FAULT CODE (ID 37)
This monitoring value indicates the fault code of latest activated fault that is not reset.
V2.2.19 FIRE MODE STATUS (ID 1597)
This monitoring value indicates the status of the Fire mode function.
V2.2.20 APPL. STATUS WORD 1 (ID 89)
This monitoring value indicates the bit coded statuses of the application.
V2.2.21 APPL. STATUS WORD 2 (ID 90)
This monitoring value indicates the bit-coded statuses of the application.
V2.2.22 DIN STATUS WORD 1 (ID 56)
This monitoring value indicates the bit-coded status of the digital input signals. A 16-bit word, where each bit
indicates the status of one digital input. Six digital inputs from each slot are read. Word 1 starts from the input 1 in
slot A (bit0) and ends with input 4 in slot C (bit15).
V2.2.23 DIN STATUS WORD 2 (ID 57)
This monitoring value indicates the bit-coded status of the digital input signals. A 16-bit word, where each bit
indicates the status of one digital input. Six digital inputs from each slot are read. Word 2 starts from the input 5 in
slot C (bit0) and ends with input 6 in slot E (bit13).
V2.2.24 MOTOR CURRENT WITH ONE DECIMAL (ID 45)
This monitoring value indicates the measured current of the motor with the fixed number of decimals and that is
less filtered.
V2.2.25 KWH TRIP COUNTER LOW (ID 1054)
This monitoring value indicates the actual value of the kWh counter (energy counter).
V2.2.26 KWH TRIP COUNTER HIGH (ID 1067)
This monitoring value indicates how many times the kWh counter (energy counter) has spun around.
V2.2.27 LAST ACTIVE FAULT ID (ID 95)
This monitoring value indicates the fault ID of latest activated fault that is not reset.
V2.2.28 LAST ACTIVE ALARM CODE (ID 74)
This monitoring value indicates the alarm code of latest activated alarm that is not reset.
V2.2.29 LAST ACTIVE ALARM ID (ID 94)
This monitoring value indicates the alarm ID of latest activated alarm that is not reset.