Scanning and Faxing
3. Press the Machine Status button.
4. Touch the Tools tab.
5. Enable the SOAP port.
a. Select Connectivity & Network Setup.
b. Select Port Settings.
c. Select SOAP and then select Change Settings.
d. Select Port Status and then select Change Settings.
e. Select Enabled then select Save.
Select Close until the Port Settings screen is displayed.
f.
6. Enable the SNMP port.
a. Select SNMP and then select Change Settings.
b. Select Port Status and then select Change Settings.
c. Select Enabled then select Save.
d. Select Close until the Port Settings screen is displayed.
e. Enable the Internet Service (HTTP) port using the same process as stated above.
f.
Select Close repeatedly until the Tools screen is displayed.
7. Set an IP address.
If an IP address is already set, this step is not necessary. Also, in an environment with DHCP or
BOOTP, configure the way to obtain an IP address. If the address cannot be obtained
automatically, or static configuration is preferred, configure an IP address, a subnet mask, and a
gateway address as follows.
a. Select Protocol Settings.
b. Select IPv4 (or other mode) Address Resolution and then select Change Settings.
c. Select one from DHCP, BOOTP, RARP, DHCP/Autonet or Static, and then select Save. If you
select anything other than Manual, proceed to Step 5.
Note:
When communicating by TCP/IP make sure to enable the use of a DNS (or WINS for SMB)
servere in CentreWare Internet Services.
d. On the Protocol Settings screen, select TCP/IP – IP Address and then Change Settings.
e. Enter the IP address using the numeric keypad.
f.
Enter the address in the format xxx.xxx.xxx.xxx. The xxx should be a numeric value in the range
from 0 to 255. However, 224 – 255.xxx.xxx.xxx and 127.xxx.xxx.xxx cannot be used.
g. Select Save.
h. Configure TCP/IP – Subnet Mask and TCP/IP – Gateway Address using the same process as
stated above.
Note:
Enter the Gateway address in the format xxx.xxx.xxx.xxx. The xxx should be a numeric value in
the range from 0 to 255. However, 224 – 255.xxx.xxx.xxx and 127.xxx.xxx.xxx cannot be used.
Note:
Specify the subnet mask by a combination of the numbers 0, 128, 192, 224, 240, 248, 252, 254,
and 255. However, you cannot use 0 between non-zero values.
If you do not set the gateway address, enter 0.0.0.0.
8. Select Close until the Tools screen is displayed.